Содержание HH02ST

Страница 1: ...English v1 3 metreco MANUAL Metreco HVAC MK1...

Страница 2: ...s and warnings indicated in this manual are marked with the following symbol IP64 dust tight splashingwater tight don t submerse or hold under tap upside down can be used in the rain Do not open in or...

Страница 3: ...Diagnosis Measurements Diagnosis 4 3 Logging Reports Logging Measurement Report Intervention Report 4 4 Tests Pressure DecayTest Vacuum DecayTest COPTest 4 5 Customer Systems follow up Follow up on M...

Страница 4: ...rements simultaneously to the Handheld no hoses no lines The user positions himself where he wants walks around and can read out the measurements in real time Intuitive natural easy to use interface i...

Страница 5: ...ooking at the All Measurements level and has an instant idea of the measured and calculated values If one of the targets is off he gets a warning with a diagnosis and a possible cause The measured val...

Страница 6: ...E Male 5 16 SAE Female 1 X connector 4 1 4 SAE Male 2T connectors 1 4 SAE Female 2 1 4 SAE Male Space for 3 extra sensors Sensors Charging LED Handheld Lid with protective foam Storage Socket for char...

Страница 7: ...ors to Main Menu start stop logging 1 4 3 2 Touchscreen Shortcuts Power sockets USB socket Power sockets ON OFF Calibration Locate Red LED Green LED Push the button while the red LED flashes 2 s Flash...

Страница 8: ...rmware see 5 3 Units Language Log interval go to 4 3 Logging Date andTime 3 Change the configurations as desired 2 Select Configurations Target margins Screen intensity 1 Go to Main Menu Modifying the...

Страница 9: ...em and turn them on by pressing at least for 2 seconds on the button 4 Observe the measured values 2 You will see the All Sensors screen In chapter 4 ACR the following applications are treated Creatin...

Страница 10: ...tem choose an existing ACR system edit current ACR system remove an existing ACR system 1 Choose New ACR System and select Client Create a new one if needed or select an existing one 2 Choose Name and...

Страница 11: ...or The sensor code will start blinking on the handheld 11 When all sensors are assigned select OK in the right bottom corner This will give you the ACR Sytem again 8 You have the possibility to assign...

Страница 12: ...e to re enter the data at each service 4 Select the customer whose system you are servicing 5 Select the ACR system 10 Observe the measured values in AllValues Choose existing ACR system 3 Select Choo...

Страница 13: ...an undo it s placement and assign it on a different spot system can be saved without sensors being placed 5 Confirm with OK 6 Save System Edit current ACR system Saved systems can be removed deleted 1...

Страница 14: ...erature at evaporator inlet Air temperature at evaporator outlet Temperature Delta of air over evaporator Pressure at condensor outlet Pressure Delta over condensor Pressure at filter outlet Pressure...

Страница 15: ...non limited list that serves only as an indication The engineer has to make his own diagnosis and has to be in possession of the certificates mandatory by law and the knowledge to service ACR systems...

Страница 16: ...the Metreco on your PC via USB This can then be used for technical or commercial purposes see 4 5 Customer Systems follow up The standard interval between 2 loggings is 5 seconds You can modify this i...

Страница 17: ...ending the logging and can be recalled on Metreco and downloaded on PC for later use in internal reports or reports to your customer 5 The Measurement Report contains a summary of customer data system...

Страница 18: ...rigerant acid test refrigerant moisture test Time spent on the job Notes 1 Select a system see 4 1 Intervention Reports can only be made when an ACR system is selected 3 Select New Intervention Report...

Страница 19: ...um sensor if placed on the installation and assigned in Metreco 11 Select the used gas N2 or N2 H2 17 Select Moisture test and enter the result 19 Select Notes and add remarks 16 Select Acid test and...

Страница 20: ...the Pressure DecayTest Setup You must assign a pressure sensor You are free to choose to assign a SystemTemperature sensor AmbientTemperature sensor Target Pressure Pressure Medium N2 or N2H2 1 Selec...

Страница 21: ...he System Temperature TargetVacuum Pressure 1 Select Main Menu and select Tests 4 Press Start Evacuation You get theVacuum Evacuation Status 5 When the wanted target vacuum is achieved stop de evacuat...

Страница 22: ...measuring the Seasonal COP 2 Select COPTest 3 Complete the COPTest Setup You must assign at least 2 pressure sensors and 3 temperature sensors A third pressure sensor is needed if your refrigerant has...

Страница 23: ...nect to your PC with the included USB cable 2 Select Open folder to view files using 3 You get 5 folders handheld data file not for manipulation lang all languages logfiles data file not for manipulat...

Страница 24: ...yTest Report long short version repeat step 1 to 6 7 Select REPORT 8 Select the wanted report type 9 Select the wanted report 10 The reports can be opened using any conventional word processor Click r...

Страница 25: ...l be lost Sensor out of range If your sensor is out of range all arrows will have disappeared in the reception area of that target sensor in the All Sensors screen see step 4 in 3 Measuring during the...

Страница 26: ...g removing and handling refrigerant 4 Hoses 1 4 SAE 1 4 SAE Red Blue Yellow 1 4 SAE 3 8 SAE Yellow 2T connectors 1 4 SAE Female 2 1 4 SAE Male 1 X connector 4 1 4 SAE Male 2 R410A adaptors 1 4 SAE Mal...

Страница 27: ...27 Evacuation 1 Evacuation 2 Evacuation 3 X connector...

Страница 28: ...han the one you have on your Metreco see step 5 below 5 2 Calibration We advice you to in the spirit of the F GAS have your sensors tested and calibrated yearly You can perform the sensor calibration...

Страница 29: ...is window and disconnect your Metreco 3 Connect the Metreco to your PC with the included USB cable 4 Select Open folder to view files using 5 Drag the downloaded file s in the dedicated folder Langaug...

Страница 30: ...n air Protection IP64 with cap closed Temperature Code Tc0150PV Name Temperature sensor Range 50 150 C Precision 0 5 C Autonomy ON 119h 5days Autonomie OFF 1 5 year Battery LiPo Lithium Ion Polymer Wi...

Страница 31: ...absolute vacuum gauge precision 0 5 50 150 C temperature sensor Velcro standard Metreco case charging station standard accessories for Metreco hoses couplers adaptors USB cable red hose 1 4 SAE 1 4 SA...

Страница 32: ...www metreco com T 32 58 42 91 00 info metreco com F 32 58 42 14 46...

Страница 33: ......