Locker Controller ELS NET Technical Manual
Each Locker Controller and Locker Extension Module has a blinking green LED operating indicator. All
these signals are under software control indicating that the device is running.
Network Communication
Network communication (Metra NET) is signalled on the Locker Controller by four LEDs:
Left Green LED is on when the Locker Controller is receiving data packets from Extension
Module(s).
Left Red LED is on when the Locker Controller is transmitting data packets to Extension
Module(s).
Right Green LED is on when the Locker Controller is receiving data packets from Metra NET
Network.
Right Red LED is on when the Locker Controller is transmitting data packets to Metra NET
Network.
Setting Operational parameters – via Metra NET Network
Metra Network Controller must be connected to Metra NET Network
Metra server must be running and all hardware added in Metra ELS/ELS NET/LCC NET software.
Each Locker Controller must have set its unique Metra NET Network address – ID.
OPTION 1 (downloading parameters to single divice at a time):
By pressing the PARAMETERS REQUEST button on the Locker Controller you trigger the request
for operating parameters.
Operating parameters are downloaded to the Locker Controller.
Check if correct operating parameters were downloaded. See chapter
“Functional Test”
for
more details
OPTION 2 (downloading parameters to all devices at once):
In Metra SW go to View\Download and click on the “Download All” button.
Operating parameters are downloaded to all devices in the Metra NET Network.