Door Access Terminal Combo Technical Manual
Relay Mode
El. Strike/Metra 3R
(
El. Strike
)
Type of relay used.
Alarm
Device Break-In
ON/OFF (
OFF
)
Not supported.
Alarm
Door opened longer
than
ON: 31 – 600 (
60
)/OFF
(
OFF
)
Alarm is triggered if the door stays opened for X
seconds.
Alarm
Door Break-In
ON/OFF (
OFF
)
Alarm is triggered if the door is opened by force.
Alarm
Alarm Time
1 – 180 (
30
)
Alarm duration in seconds.
Pushbutton input
ON/OFF (
OFF
)
Door can be opened by pressing the pushbutton.
Pushbutton must be installed and connected.
Time Checking
ON (From: 00:00-23:59 –
to: 00:00-23:59) per each
day of week/OFF (
OFF
)
Entrance with user card is possible from XX:XX to
XX:XX if time checking is ON. If set to OFF,
entrance is always possible.
Lockers
ON (1-9999)/OFF (
OFF
)
Entrance with user card is possible if user card
has one or more set lockers assigned to it.
There are various ways of setting the operating parameters.
Setting Operational parameters - via Metra NET Network
Operating parameters are obtained through the Metra NET Network. The server must be set up and
running for that purpose. To obtain operating parameters, press the PARAMETERS REQUEST button
(number
in the paragraph
“DIP switch settings”
).
NOTE
Network based functionality will be present only if the server is running and the Door Access
Terminal has been properly configured.
NOTE
Metra software automatically updates operating parameters on the device if you change them.
Setting Operational parameters - via serial port by PC
You can download the operating parameters from the template file with LCC Download
software.
Consult LCC Download Software User Manual for more information.
Maintenance
No regular maintenance is needed.
Содержание Door Access Terminal Combo
Страница 1: ...Door Access Terminal Combo Technical Manual ...
Страница 18: ...Appendix 1 Door Access Terminal Combo Physical dimensions User interface 89 147 2 37 1 4 8 10 ...
Страница 19: ...Appendix 2 Door Access Terminal Combo Physical dimensions Control module 40 232 105 40 232 105 ...
Страница 20: ...Appendix 3 Door Access Terminal Combo Physical dimensions User interface mounting holes 8 60 90 52 60 ...
Страница 21: ...Appendix 4 Door Access Terminal Combo Physical dimensions Control module mounting holes 60 30 120 157 36 7 ...
Страница 22: ...Appendix 5 Door Access Terminal Inner connections 1 2 5 3 4 6 7 8 ...