background image

Electric heated boiling top units (600)      9/23

appliance installed to the terminals, marked by
the symbol

(unipotential system).

Important information specifically relating to
appliances in the DROP-IN series

– The appliance must be installed in strict

compliance with the directions given in the
attached drawings.

– Appliances should only be installed on units

made of metal (and not wood and/or other
flammable materials).

– Take particular care with the power lead: the

channelways must be perfectly smooth with no
sharp corners and/or edges. The lead must not, at
any point, be subjected to temperatures of more
than 50

°

C above normal room temperature.

START

-

UP

Function check electrical system

– Start-up the appliance following the instructions

given; check function regularity  and make sure
that the controls and heating elements are in good
working order, testing them with the various
function positions.

– Each heating plate is equipped, further to the

working thermostat, with a temperature limiter
with automatic reset which cuts off the electrical
supply of the heating plate in case of overheating.

– The plate resets automatically after the tempe-

rature of the plate has cooled down.

Nominal heat input check

– After installation and at each maintenance

intervention check the heat input of the
appliance.

– The nominal heat input is stated in the

“Technical data” table.

– The appliance operates at the nominal heat

input when the electrical power is the one stated
in Table T1.

ATTENTION

If  the  power supply value is not within the limits
indicated in Table T1, interrupt the operation of
the appliance and contact the electricity delivery
body.

ANALYSIS

 

OF

 

SEVERAL

 

FAILURES

Hot plate do not heat up

– Check fuse valves
– Main switch off
– Insufficient power or wrong electrical connection
– Change-over switch faulty
– Hot plate faulty or wrong connecting
– Temperature regulator cut off activated or

faulty.

REPLACEMENT

 

OF

 

PARTS

 

SUBJECT

 

TO

 

CHANGE

IMPORTANT

Before carrying out repairs, unplug appliance from
mains disconnecting the main switch.

INSTALLATION INSTRUCTIONS

WARNINGS

Installation, adjustments and maintenance of the
appliances must be done by authorized installers,
in accordance with the safety standards in force.

The manufacturer declines any responsibility
if such obligation is not observed.

INSTALLATION

Positioning

– The overall/connection dimensions and the

technical data are stated in the pages in the
appendix.

– Install the appliances only in sufficiently aired

rooms.

– Position appliances at least 5 cm from the nearby

walls.

– The appliances are not suitable for built-in

installation.

Assembly

– Remove the film which protects the external

panels. Any glue remaining on these is to be
removed with a suitable solvent.

– Assemble the spacer (if foreseen) by following

the instructions enclosed with the spacer itself.

In line union of the appliances

– Put the appliances next to eachother and level

them at the same height.

– Unite the appliances using the special union

joint-coverings supplied upon request.

Electrical connections

– Appliances are designed to operate at the voltage

indicated on the rating plate.

– Each appliance must be connected to an

independent mains supply of suitable capacity
(total power indicated in “Technical data” table)
via an input terminal board with flexible rubber
cable, insulated at a level not below H07RN-F.

– Make sure that the cables lenght allows for the

live wires to disconnect from terminal block
before the yellow/green ground wire, in case of
simultaneous pull.

– Automatic cutout omnipolar switches of suitable

capacity (with contacts opening to at least 3
mm) and highly sensitive automatic differential
protective devices must be fitted. These must
ensure that there is no direct or indirect contact
between live components and fault currents
and the ground, in accordance with current
regulations (maximum admissible leakage
current 1 mA/kW).

Earth and unipotential connections

– Appliances must be earthed on terminals marked

with the symbol        .

– Connect the metallic structure of every electrical

Отзывы: