![Metos Master AQUA 50 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/metos/master-aqua-50/master-aqua-50_installation-and-operation-manual_1777992016.webp)
EN
page 34
USER SECTION
6. MAINTENANCE
6.1
Regular Maintenance
WARNING: The machine is not protected against water jets, therefore do
not use pressure cleaning systems.
Contact your cleaning products retailer for detailed instructions on the
methods and products to use for periodic sanitizing of your appliance.
DO NOT use bleach or chlorine-based detergents for cleaning the ap-
pliance.
In order to ensure perfect performance, the appliance must be completely cleaned at least
once a day in the following way:
• Turn the main switch to 0.
• Turn off the water tap.
• Remove the overflow tube to empty the water.
For appliances provided with emptying pump follow the indications as described on
paragraph 5.3.
• Remove the filter and clean it with a brush under running water.
• Remove the rotors by loosening the fixing screws, and thoroughly clean the nozzles and
cleaning and rinsing arms under running water.
• Reassemble all parts and refit the rotors in their seats, fixing them with the relative
screws.
• Clean the tub thoroughly using specific products.
• At the end of the day, it is advisable to leave the dishwasher door open.
N.B.: It is advisable to replace the tub water by refilling the tub at least every 20 wash
cycles, or twice a day. Do not use metal brushes or corrosive products which can
damage the machine.
6.2
Special Maintenance
Once or twice a year have a qualified technician inspect the machine:
1 To clean the electrovalve filter.
2 To remove residual deposits.
3 To check the holding capacity of the piston seals.
4 The condition and/or wear of the components.
5 The operation of the dispensers.
7. ALARMS
TYPE OF ALARM
CAUSE
REMEDIES
Flashing of the cycle
lamp
Missed refill of water in the
wash-tank
Verify the full opening of the
water inlet valve or the right
positioning of the overflow pipe.
Switch the machine OFF and
ON to reset the alarm
Missed heating of the water
boiler (in machines equip-
ped with Termostop)
Boiler thermostat or boiler
heating element out of order.
Check them or call for Service
Flashing of the softening
lamp
Missed tank emptying
remove the overflow pipe and
drain the tank. Switch the
machine OFF and ON to reset
the alarm