METHVEN ROUND DRY RAIL Скачать руководство пользователя страница 2

 

 

Inlet Connector 

Rail

Rail

Slider

Slider

Rail End Cap

Grub Screw

Mounting

Screw

Bottom Rail 

Connector

Elbow

Grub Screw

Soap Dish

Soap Dish

½" BSP Nipple

(Not Supplied)

Connecting Nipple 

Grub Screw

Grub Screw

Mounting

Screw

Inlet Connector 

Bottom Rail 

Connector

Mounting

Screw

• 

This product must be installed in compliance with all relevant regional regulations.

• 

It is the responsibility of the installer to ensure a waterproof seal is achieved between the 

product and mounting surface. If in doubt about the quality of the seal, remove the product 

and reinstall using silicone to ensure a seal is achieved. 

• 

All pipe work must be thoroughly flushed prior to the installation of the hose.

• 

After installation all connections must be checked for leaks.

• 

All outlets used primarily for personal hygiene shall deliver water at a safe temperature as 

per regional regulations.

Wet Rail

Step 1

•  Install ½” BSP nipple 

at the desired 

top 

bracket

 position.

•  Wall lining hole should 

be cut or finished as 

per the dimension 

shown in the diagram 

on the right.

•  Cut off the threaded 

nipple 13±2mm from 

the wall lining and 

apply thread seal tape 

to ensure a good seal.

Step 2 

•  Screw the inlet 

connector onto the 

nipple.

Step 3

•  Slide the soap dish and 

bottom rail bracket 

onto the rail. Check the 

grub screw is located 

on the bottom side of 

the rail bracket.

Dry Rail

Step 1 

•  Fix the connecting nipple 

to the wall at the desired 

top bracket position using 

the mounting screw 

provided.

•  Screw the inlet connector 

onto the nipple.

Step 2

•  Slide the soap dish and 

bottom rail bracket onto 

the rail. Check the grub 

screw is located on the 

bottom side of the rail 

bracket.

•  Ensure that the washer is 

in the rail end cap and 

screw it to the bottom of 

the rail. 

Step 3

•  Install ½” BSP 

nipple at the desired 

elbow

 position.

•  Wall lining hole should be 

cut or finished as per the 

dimension shown in the 

diagram on the right.

•  Cut off the threaded 

nipple 13±2mm from the 

wall lining and apply 

thread seal tape to ensure 

a good seal.

•  Screw the elbow onto the 

nipple ensuring that the 

o-ring is sufficiently 

compressed to create a 

watertight seal.

IMPORTANT: 

Please read all of the instructions before installation.

General:

Installation:

13±2mm

26mm 

max 

13±2mm

26mm 

max 

Wet Rail Installation