background image

Faceplate

Allen Key

Grub Screw

Body assembly

Lever Handle

Half Dome

Technical Specification

Inlet Connections: 

All 1/2" BSP

Operating Pressure: 

150kPa - 500kPa

 

For optimum performance hot and cold water pressures should be equal.

 

AS/NZS 3500 stipulates a 500kPa maximum operating pressure at any outlet  

 

within a building. Where normal pressure exceeds 500kPa, a pressure limiting  

 

valve must be installed.

Operating Temperature: 

Recommended hot water supply 50°C, maximum 70°C. AS/NZS 3500 requires all  

 

hot water supplies to any sanitary fitting to be tempered to 50°C.

Ceramic cartridges: 

The ceramic cartridge can be damaged due to the presence of the following within 

 

the water supply:

 

Copper tube pieces

 

Plastic pieces

 

Sand, dirt or stones

 

Thread tape

 

Other objects not normally present in the potable water supplies

Piping Requirements for Mixers

Avoid restrictive piping, fitting or sharp angled bends when plumbing the mixer. 
Do not hydrostatic test* the installation with this mixer installed. Damage to the ceramic cartridge may occur. 

*Hydrostatic testing refers to placing the system under pressure, above the recommended operating pressure, to 

determine water tightness and to uncover leaks or weak joints within the system.

Care and Cleaning

Never use abrasives to clean this product. Clean regularly with contamination free warm soapy water and a damp 

soft cloth. 

www.methven.com

Customer Care Hotline: 1300 METHVEN (638 483)

Email: [email protected]