8.1 Password Verification

“PA” stands for “Password”. ”0000” are the digits of the password.

 

Set the password by pressing the “Down” button to decrease the digit value, or “Up” to increase the value.

Password is 8888.  Press the “   ” eight times (to get to 8) press “SET” button

 

and the marker will move to the next digit which

should automatically default to 8.  Press “SET”

 four

 times to move onto the next setting.

8.2 ID Setting

After entering the password, the meter will ask for the address range.  Enter 1 if you are not using Mbus.

Example below ”Id 00” shows that the current ID address is 00 (the ID address is hex code)

Address should be between 1 - 250

Use the “Down” button to decrease the digit or ”Up” to increase the digit value.  Press the “SET” button to save the 

digit and move onto the next digit.

8.3 Baud rate setting

Press “SET” button to bypass entering the Baud rate.

Press “Down” and “Up” buttons to select the communication baud rate, press “SET” button to save the setup.

The interface will enter CT setup.

Note:

The default baud rate will be set at 1200 bps

3MB100 

ID      00

s a l e s @ m e t e r s . c o . u k    |    W h i t e  L u n d  I n d u s t r i a l  E s t a t e  L a n c a s t e r  L A 3  3 B T   |    0 1 5 2 4  5 5 5  9 2 9

8. PROGRAMMING

By holding the keys “SET” pressed for at last 3 seconds  

The meter will go into programming mode.  

Baud Rate = bits per second.  This is the rate that devices exchange information online (on the RS485 network).
All devices MUST BE SENT at the SAME rate otherwise they cannot communicate.
Common Baud rate settings for M-Bus : 300; 2400

PA  0000

L1

L3

rev

L2

000375

.

5

000123456789

E M 7 3 5 - M o d

I E C 6 2 0 5 3 - 2 1    : 2 0 1 6
3 x 2 3 0 / 4 0 0 V   3 x 1 0 ( 1 0 0 ) A   5 0 /

6 0 H z

METERSUK

LTD

bd  2400

Содержание 3MB100

Страница 1: ...g Memory back up EEprom 7 DIN module size METERSUK L T D 1 SAFETY NOTICE The smart energy meter 3 MB 100 does not require special mechanical or electrical tools for its installation Mounting position...

Страница 2: ...C to 55 C 3k6 75 yearly average 95 on 30 days per year EN50470 3 IEC62053 21 CI 1 IP51 0 16mm 0 2 5mm Direct Connection Current A Lref Ltr Lmax Lmin Ist General data Frequency Hz Memory back up upper...

Страница 3: ...10 24 17 12 19 14 21 9 23 16 11 18 13 20 1 3 5 7 2 4 6 LINE 1 IN LINE 1 OUT LINE 2 OUT LINE 3 OUT LINE 2 IN LINE 3 IN NEUTRAL IN 21 22 M Bus Communication 23 24 Pulse Output 23 24 Pulse Width 80m sec...

Страница 4: ...the minimum bus voltage at any device must not be lower than 24 V 36 V 24 V 12 V The cable resistance therefore limits the maximum possible cable length from the MBus Master Repeater to the device wi...

Страница 5: ...gy They are test pulse output pins 23 24 Usually the test pulse output is used as testing accuracy or reading purpose in close quarters passive transistor output requiring an external voltage source f...

Страница 6: ...ue Press the SET button to save the digit and move onto the next digit 8 3 Baud rate setting Press SET button to bypass entering the Baud rate Press Down and Up buttons to select the communication bau...

Страница 7: ...complete the meter will automatically save the password after 30 seconds or when powered off PLEASE NOTE It is important to take a note of the new password as one cannot bypass the system If the passw...

Отзывы: