3

INSTALLATION

Table 1  Installation (continued)

Preparation

Conduct System Check
METER strongly recommends setting up and testing the system (sensors and 

data loggers) in the lab or office.

Inspect and verify all components are intact. 

Visit the data logger product page for the most up-to-date software and firmware. 

Verify all sensors are functional and read within expected ranges.

Consider the Surroundings
For measurement of incoming PPFD in the outdoor environment, choose a 

location that allows the sensor to be above the plant canopy or in a position 

where the view of the sky is unobstructed (such as a large canopy gap or forest 

clearing). 

Ensure the sensor is not shaded from nearby objects (weather stations, 

mounting posts, etc.).

Mounting

Install on Mounting Post
Use the U-bolt to mount the mounting bracket and sensor assembly 

(

Section 2.1

). The U-bolt is compatible with most meterological stands, poles, 

tripods, and other mounts. 

Ensure the sensor is oriented so the cable points toward true North (in the 

Northern hemisphere) or true South (in the Southern hemisphere) to reduce 

azimuth error. 

Secure the System
Tighten the U-bolt nuts by hand until hand-tight, and then tighten with a wrench.

CAUTION:  Do not overtighten U-bolt.

Adjust the three machine screws on the leveling plate until the integrated 

bubble level indicates that the sensor is level

Secure and Protect Cables

NOTE:  Improperly protected cables can lead to severed cables or disconnected sensors. 
Cabling issues can be caused by many factors such as rodent damage, driving over sensor 
cables, tripping over cables, not leaving enough cable slack during installation, or poor 
sensor wiring connections. 

Install cables in conduit or plastic cladding when near the ground to avoid 

rodent damage. 

Gather and secure cables between the sensors and the data logger to the 

mounting post in one or more places to ensure cable weight does not pull the 

plug free from its port.

Connect to Data Logger
Plug the sensor into a data logger.

Use the data logger to make sure the sensor is reading properly.

Verify these readings are within expected ranges.

For more instructions on connecting to data loggers, refer t

Section 2.2.

Содержание APOGEE SQ-521

Страница 1: ...APOGEE QUANTUM SENSOR...

Страница 2: ...CONTENTS 1 Introduction 2 2 Installation 2 2 1 Set Up Mounting Assembly 4 2 2 Connect to METER ZENTRA Series Logger 5 3 Data Interpretation 6 4 Troubleshooting 6 5 Customer Support 7 Index 8 18474 01...

Страница 3: ...p a g e e I N S T R U M E N T S Made in USA...

Страница 4: ...data loggers Details of how the ZENTRA system handles the data are also included Please read this document carefully in its entirety before going out to the field For more information on the Apogee Fu...

Страница 5: ...rd true North in the Northern hemisphere or true South in the Southern hemisphere to reduce azimuth error Secure the System Tighten the U bolt nuts by hand until hand tight and then tighten with a wre...

Страница 6: ...the sensor M8 connector holes and seat connectors fully 2 Tighten the cable screw until hand tight Figure 1 M8 connectors are easy to overtighten Do not use pliers or other tools to tighten this conn...

Страница 7: ...TRA data loggers 1 Plug the stereo plug connector into one of the sensor ports on the logger Figure 4 Port 1 Port 2 Port 3 Port 4 Port 5 Port 6 TEST OK ERROR Conduit Figure 4 Logger connection 2 Conne...

Страница 8: ...t responding Check power to the sensor and logger Check sensor cable and stereo plug connector integrity Check that the SDI 12 address of the sensor is 0 factory default Check this with ZENTRA Utility...

Страница 9: ...600 Fax 1 509 332 5158 Website metergroup com EUROPE Customer support representatives are available for questions problems or feedback Monday through Friday 8 00 to 17 00 Central European time Email s...

Страница 10: ...tallation 2 3 mounting 3 preparation 3 tools needed 2 M mounting 3 mounting bracket 2 4 P photosynthetic photon flux density 2 3 4 6 Q Quantum sensor 2 4 6 R recalibration 6 S stereo plug connector 5...

Страница 11: ...ins Court Pullman WA 99163 T 1 509 332 2756 F 1 509 332 5158 E info metergroup com W metergroup com METER Group AG Mettlacher Stra e 8 81379 M nchen T 49 89 1266520 F 49 89 12665220 E info europe mete...

Страница 12: ......

Отзывы: