OPERATION
2. OPERATION
Please read all instructions before operating the ATMOS 14 to ensure it performs to its full
potential.
PRECAUTIONS
METER sensors are built to the highest standards, but misuse, improper protection,
or improper installation may damage the sensor and possibly void the manufacturer’s
warranty. Before integrating ATMOS 14 into a system, follow the recommended installation
instructions and have the proper protections in place to safeguard sensors from damage.
2.1 INSTALLATION
In general, temperature and humidity measurements become more accurate as wind speed
increases. For most outdoor and greenhouse measurement scenarios, the ATMOS 14 must
be housed in a radiation shield with adequate air flow to allow the sensor to come into
equilibrium with air temperature. For nongreenhouse, indoor monitoring applications, a
radiation shield is not critical because the radiation loading is small.
Follow the steps listed in
to set up the ATMOS 14 and start collecting data.
Table 1 Installation
Tools Needed
Wrench
Mounting pole
Preparation
Consider the Surroundings
Ensure that site selection is far from wind obstruction and objects that can
store heat.
Conduct System Check
Plug the sensor into the logger (
) to make sure the sensor is
functional.
Adjust Pole Height
Check Radiation Shield
Ensure the sensor is securely installed in the radiation shield.