3
ATMOS 14 GEN 2
Table 1 Installation (continued)
Mounting
Install on Mounting Pole
Use the radiation shield mounting bracket and V-bolt to mount the radiation
shield to the mounting pole at the desired height.
Secure the System
Use a wrench to tighten the bolts, securing the radiation shield to the
mounting pole.
Secure and Protect Cables
NOTE: Improperly protected cables can lead to severed cables or disconnected sensors.
Cabling issues can be caused by many factors such as rodent damage, driving over sensor
cables, tripping over cables, not leaving enough cable slack during installation, or poor
sensor wiring connections.
Install cables in conduit or plastic cladding when near the ground to avoid
rodent damage.
Gather and secure cables between the ATMOS 14 and the data logger to the
mounting mast in one or more places.
Connect to Data Logger
Plug the sensor into a data logger.
Use the data logger to make sure the sensor is reading properly.
Verify these readings are within expected ranges.
For more instructions on connecting to data loggers, refer to
.