background image

Wiring Diagram

DMX

Black(Line)

Green(Ground)

White(Neutral)

Brown(Line)

Green(Ground)

Blue(Neutral)

LED

Fixture

AC Input

Connect DMX by using a standard DMX512 XLR cable 
with 5 pin in/out connector (by others). 

Connect DMX by using a standard shielded CAT5/6 
cable.

*The last fixture has to be terminated with a DMX Terminator (by others).

1.   DMX is a digital three-wire system. Use all three! 
2.   DMX is based on the EIA-485/RS-485 standard.
3.   Always use cable specifically designed for DMX / RS-485. These cables have an impedance of 120

Ω 

 and a 

      low capacitance. For instance : Belden 9841 or 3105a.
4.   DMX must be terminated with a 120

Ω 

resistor to prevent reflections.

5.   A daisy chain topology should be used.
6.   After 32 unit loads a repeater/booster should be used.
      (Important : For tunable white fixtures, After “32” unit loads a repeater/booster should be used.)
7.   Keep cabling below 200 meters between the controller and the last driver.
8.   It is generally considered good practice to provide separate DMX in and DMX out / DMX thru connections 
      to your fixture to aid in installation. This can be in the form of pigtails, RJ-45 connectors or 5-pin XLR 
      connectors.
9.   Use twisted pair cables with an impedance of 120

Ω 

 and a low capacitance.

10. UTP Cat5 or Cat6 network cable can also be used but have a slightly lower impedance of 100

Ω

.

11. If shielded cable is used, only connect shield to ground on one side (typically, the controller should have its 
      shield terminal connected to ground).
12. Not following the above recommendations may seem to work at first, but can cause problems. Sometimes 
      after weeks of seemingly normal operation. 

DMX/RDM is a robust and reliable system for lighting control. However, if not implemented correctly, problems can arise such as 
random flashing of lights, erratic operation and delays in responding to commands. This document explains the best practices 
in DMX wiring.

Application note : Wiring for DMX/RDM lighting systems

Important things to consider are:

XLR

DMX Box

RJ45

DMX Box

Page 5

Installation Instructions

Atria 10 - Adjustable Cable

ADVANCED HIGH CEILING  

METEOR LIGHTING     

P: 213.255.2060     F: 213.596.3704     www.meteor-lighting.com

*METEOR LIGHTING reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately.

Отзывы: