9
Water Supply Connection
The water inlet nozzle connector is supplied and should be fitted to the outside
of the machine facing upwards. It has two possible inlet locations, one on either
side of the machine, whichever is more convenient for your installation.
1.
Thread the water inlet valve (1) onto the elbow joint (2), ensuring a fibre
washer (4) is placed between the two.
Ensure the valve is tightened securely to eliminate leakages
.
2.
Take the water inlet bush (3) with a fibre washer (4) placed over it and feed
through the chamber wall from the inside.
3.
Place another fibre washer (4) onto the water inlet bush on the exterior side of the chamber. Take
the assembly from step 1 and thread the remaining elbow joint opening onto the water inlet bush.
Ensure the assembly is tightened securely to eliminate leakages. Also ensure the water inlet
valve is pointing directly upwards, otherwise the air gap does not function correctly.
Connect the water supply pipe to the water inlet, connect the other end of the supply pipe to a cold water
tap or shut off valve that can be used to supply a sufficient water flow into the machine.
Waste Outlet Connection
The waste outlet is screwed onto the right-hand side of the machine but can be
used on either side of the machine to suit your installation. Pipe work for the
waste outlet can be purchased from a hardware store, or we can supply as an
optional extra a waste pipe, elbow and coupling. This is to be fitted to the waste
outlet casting to discharge the waste into a sink.
Having connected the water inlet, waste outlet and the electrical supply, the machine is ready for