8

SET-UP MODE & CALIBRATION

The Set-up mode will allow you to change some settings of the QX2 system. To enter
this mode, turn off the main power, hold down the +/- keys simultaneously and turn
the main power on. 

The LCD will display a prompt to enter an Access Code. Use the +/- buttons to
change the number of your code. The default code from the factory is “000”. Push the
Start/Stop Button to submit the code and enter the Set-up Mode.

A form for you to write down your code is provided with the unit. It also tells you
the universal access code number that will always work in case you forget your code.
You may wish to  store it separately.

Once you are in the Set-up mode you will have the menu options listed below. 

Cycles: Displays the number of Remove and Attach cycles that the system has run.

Hours: Displays the cumulative run time.

Temp Units: The default setting for this is ˚C. The set up mode offers you the option
of changing this to ˚F by pushing the + or - button.

Setpoint: The default temperature is set to 350˚C. This is the temperature of the air
exiting the heater. If you wish to adjust this set point, you can hold down the +/-
keys to set the desired temperature. The setpoint can be adjusted between 250˚C
and 450˚C. Unless you have unusual process conditions, it should not be necessary
to change the setpoint. 

Display: The default setting is for the controller to display the temperature of the air
exiting the heater. By pushing the + or - button, you can change this setting to have
the controller display the temperature from the auxiliary thermocouple port.

New Code: Allows you to change the Access Code used to enter the Set-Up mode.
Use +/- to change the code.

Calibrate: Allows you to enter the calibration mode. Use + or - to change to “Y” and
then push the Start/Stop Button.  The calibration procedure requires a Thermocouple
Calibrator.  Please contact Metcal Customer Care for assistance.

Set Defaults: Allows you to return all settings to the factory defaults.  The following
are the factory settings:

Access Code:

000

Temp Units:

˚C

Setpoint:

350˚C

Display:

Internal

Calibrate:

none (clears any new calibration settings)

For all the menu options, pushing the Start/Stop Button enters your changes and
cycles to the next option. To exit the Set-up mode, turn the main power off.

Copyright 

©

1999, Metcal, Inc. All Rights Reserved  7036-0541 Rev. A

9

BOARD HOLDER 

OVERVIEW

The board holder provides a self-centering mechanism for holding a PCB from
50 mm x 50 mm  to 360 mm x 460 mm in size horizontally at a distance of 120 mm
from the workbench surface.

SET-UP

Place the board holder on a workbench with a level surface. The unit is now
ready for use.

OPERATION

Rotate the wheel of the board holder assembly clockwise or counterclockwise to
move the clamp rail in or out to accommodate the size of the PCB to be reworked

Position the PCB between the clamps. The clamps may be adjusted by sliding them
along the rails, to avoid interference with any components on the edge of the PCB.
They should support each corner equally if possible. Tighten the clamps gently by
rotating the wheel. Do not overtighten: the PCB may break or the clamps may be
damaged. The clamps will flex to accommodate thermal expansion of the PCB during
the rework process.

Wheel

Clamp

Rail

Содержание QX2

Страница 1: ...national Company Copyright 1999 Metcal Inc All Rights Reserved 7036 0540 Rev A METCAL QX2 CONVECTION REWORK SYSTEM USER GUIDE Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 Te...

Страница 2: ...P MODE CALIBRATION 8 BOARD HOLDER OVERVIEW SET UP OPERATION 9 PREHEATER OVERVIEW SET UP OPERATION 10 VACUUM CUP ATTACHMENT REMOVAL MAINTENANCE 11 NOZZLE ATTACHMENT REMOVAL 12 FOCUSED CONVECTION NOZZLE...

Страница 3: ...vacuum and heat It has a movable arm that holds the heater head assembly which contains the heating element and the vacuum pick up Because no additional tool stand or work frame is needed the QX2 save...

Страница 4: ...ing the QX2 in places where there are combustible materials Never use the system in the presence of an explosive atmosphere Be aware of your surroundings heat may be transferred to materials which are...

Страница 5: ...ng from the flutes of the nozzle andthetimercountingup WARNING The nozzle and the exhausted air will be hot If you have a preheater that is properly connected to the power supply the preheater will st...

Страница 6: ...roller display the temperature from the auxiliary thermocouple port New Code Allows you to change the Access Code used to enter the Set Up mode Use to change the code Calibrate Allows you to enter the...

Страница 7: ...while minimizing the possibility of warping the PCB SET UP Plug the phone style cable into the jack on the bottom of the preheater Place the preheater on a suitable workbench and stretch out the powe...

Страница 8: ...the heater head WARNING The nozzle may be hot Copyright 1999 Metcal Inc All Rights Reserved 7036 0541 Rev A 13 FOCUSED CONVECTION NOZZLES Nozzle P N Component Type NZ Q11 PLCC 20 NZ Q13 PLCC 28 NZ Q1...

Страница 9: ...t Metcal Customer Care Same as above except it Vacuum cup is too cold and Hold the top of the vacuum tube for at least five mainly occurs when the therefore too stiff to hold seconds until the vacuum...

Страница 10: ...odified repaired altered misused or damaged unit RETURN PROCEDURE Call Metcal at 44 1703 489100 to obtain a returned material authorization RMA number Proof and date of purchase must be on file for th...

Отзывы: