Notice: 

Replace filters at least every 6 months, as most gas-phase filter media achieve saturation by 

adsorbing moisture from ambient air. 

Use only original

 

replacement filters. 

 

5.3. 

Safety Interlock

 

The safety switch is an interlock which turns off the fan when the main 
filter is removed and when the fan inlet opening is exposed. The safety 
switch also prevents the system from operating without filters in which 
case the impurities would contaminate the internal unit.  
 

WARNING! 

Do not bypass safety interlock. Bypassing safety interlock could result in 
injury to persons. 
 

5.4. 

Filter Replacement Procedure:

 

1.  Turn unit off. 
2.  Disconnect the power cord. 
3.  Unlatch the filter cover (see illustration on right). 
4.  Remove filter cover. 
5.  Replace the filters. (Pre-filter/main filter). Ensure to place main filter inside the alignment pins 

so that interlock switch is depressed. 

6.  Replace filter cover and ensure proper fit on bottom housing. Hook both latches into filter 

cover and press down carefully. 

Caution!  

Do not use force. If latches do not close, check proper seating of filter cover on bottom 
housing. 

7.  Reconnect power cord and turn system on. 
8.  If unit does not operate, refer to troubleshooting section. 
 
 

Notice: 

Always use new replacement filters! 

 

 
 

Содержание bvx-201

Страница 1: ...BVX 200 7100 0072_C Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...

Страница 2: ...the highest level of support and customer service to you This document has been prepared to guide you with the setup operation and user maintenance of your system We recommend that you review it to op...

Страница 3: ...els well below the lower explosive limits WARNING Do not use the Unit to extract corrosive substances WARNING Do not expose the connecting cable to heat oil or sharp edges WARNING Make sure the Unit s...

Страница 4: ...afe housing UL CSA listed CE certified 1 6 Usage The Fume Extraction System is a portable two station filtration system for the removal of fumes light dust or vapors at the work place The filter set s...

Страница 5: ...turned into your work area Contact your local Metcal representative if there are any questions regarding the proper selection of filters for your application When the filters are blocked an alarm will...

Страница 6: ...flux residue to adhere to the blower and decrease the life of the system and increase noise Do not lift system while operating Be sure to handle filters with care 5 2 Filter Replacement Timing Model...

Страница 7: ...g safety interlock could result in injury to persons 5 4 Filter Replacement Procedure 1 Turn unit off 2 Disconnect the power cord 3 Unlatch the filter cover see illustration on right 4 Remove filter c...

Страница 8: ...00 temperature setting to prevent false alarms 1 Assemble the BVX 200 as per the User Guide Both the remote switch the main power switch should be in the Off position 2 Switch On the main unit and pre...

Страница 9: ...t with 2 each C Clamps BVX CH01 Connection Hose 1 8m 6 x 50mm 2 BVX CH02 Connection Hose 3 6m 12 x 50mm 2 8 WARRANTY Metcal warrants the BVX 200 Series against any defects in materials or workmanship...

Отзывы: