Filter Disposal
When used in soldering applications, the HEPA and pre-filters collect particles and may be disposed
without restrictions. The filters have been EPA tested and certified non-hazardous waste for TCLP
(Toxicity Characteristic Leaching Procedure) Test Method 1311 (Extraction) as defined by EPA
standards.
The gas filters collect some organic materials and care in disposal may be required. The filters may
contain toxic materials and inhalation of dust particulate or exposure to skin must be avoided. Please
consult the MSDS’s for the materials used at your facility and follow the prescribed handling instructions.
MAINTENANCE and SAFETY
The BVX-100 is designed with low maintenance in mind. The housing is aluminum finished with high
quality ESD safe powder coat paint. The plenum and arm are ESD safe plastic. Here are a few tips to
keep your system running in top shape:
1. To clean, use a light wipe with a gentle cleaner to prevent build-up of particulates and flux residue
(be sure unit is turned off while cleaning).
2. Do not block the exhaust outlets; this will cause the operating temperature of the system to rise,
potentially damaging the unit, and drop in performance.
3. Do not defeat the filter interlock switch. Running the system without a filter will allow particulates
and flux residue to adhere to the blower and decrease the life of the system and increase the
noise.
4. Be sure to handle the filters appropriately (See FILTRATION).
5. Do not lift system while operating
TROUBLESHOOTING
Symptom
Possible Cause
Solution
LED does not illuminate
No power
Check electrical outlet for output
Check On/Off switch
Check power cords
Check for main filter
Check for safety interlock switch
LED orange
Blocked filter or
air flow
Change filter (See Replacement of Filters. Note:
change pre-filter first. If the LED is still orange,
replace the filter.)
Little air flow
Air leak
Housing not installed correctly
Arm adaptor not installed correctly
No air flow
Blower does not
work
No electrical power
Interlock switch
open
No filter installed
Housing not closed correctly
Please call METCAL if: your system is still not working properly, or if the LED is green with no air flow.