Metcal BVX-100 Скачать руководство пользователя страница 4

Filter Disposal 

When used in soldering applications, the HEPA and pre-filters collect particles and may be disposed 

without restrictions. The filters have been EPA tested and certified non-hazardous waste for TCLP 

(Toxicity Characteristic Leaching Procedure) Test Method 1311 (Extraction) as defined by EPA 

standards. 

The gas filters collect some organic materials and care in disposal may be required. The filters may 

contain toxic materials and inhalation of dust particulate or exposure to skin must be avoided. Please 

consult the MSDS’s for the materials used at your facility and follow the prescribed handling instructions. 

MAINTENANCE and SAFETY 

The BVX-100 is designed with low maintenance in mind. The housing is aluminum finished with high 

quality ESD safe powder coat paint. The plenum and arm are ESD safe plastic. Here are a few tips to 

keep your system running in top shape: 

1. To clean, use a light wipe with a gentle cleaner to prevent build-up of particulates and flux residue

(be sure unit is turned off while cleaning).

2. Do not block the exhaust outlets; this will cause the operating temperature of the system to rise,

potentially damaging the unit, and drop in performance.

3. Do not defeat the filter interlock switch. Running the system without a filter will allow particulates

and flux residue to adhere to the blower and decrease the life of the system and increase the

noise.

4. Be sure to handle the filters appropriately (See FILTRATION).

5. Do not lift system while operating

TROUBLESHOOTING 

Symptom

 

Possible Cause

 

Solution

 

LED does not illuminate 

No power 

Check electrical outlet for output 

Check On/Off switch 

Check power cords 

Check for main filter 

Check for safety interlock switch 

LED orange 

Blocked filter or 

air flow 

Change filter (See Replacement of Filters. Note: 

change pre-filter first. If the LED is still orange, 

replace the filter.) 

Little air flow 

Air leak 

Housing not installed correctly 

Arm adaptor not installed correctly 

No air flow 

Blower does not 

work 

No electrical power 

Interlock switch 

open 

No filter installed 

Housing not closed correctly 

Please call METCAL if: your system is still not working properly, or if the LED is green with no air flow. 