7000-3320 1 

 

MFR PUMP REPLACEMENT (AC-PM1) 

SWITCH OFF POWER AND UNPLUG UNIT FROM 

POWER OUTLET BEFORE SERVICING 

 

a)  Remove the power switch activator 

item 1 by pulling straight out (use a 
pliers be careful not to damage 
plastic part). 

b)  Turn unit over and remove the 4 

screws item 2 and lift top cover item 
3 off. 

c)  Unplug the vacuum line item 4 from 

pump item 5 and disconnect its 
electrical connector from the PCBA. 

d)  Remove the 3 nuts from item 6 by 

holding the pump down. 

e)  To replace pump repeat steps a) 

through e) in reverse. 

 

3

4

5

2

1

6

7000-3320 1 

 

MFR PUMP REPLACEMENT (AC-PM1) 

SWITCH OFF POWER AND UNPLUG UNIT FROM 

POWER OUTLET BEFORE SERVICING 

 

a)

  Remove the power switch activator 

item 1 by pulling straight out (use a 
pliers be careful not to damage 
plastic part). 

b)

  Turn unit over and remove the 4 

screws item 2 and lift top cover item 
3 off. 

c)

  Unplug the vacuum line item 4 from 

pump item 5 and disconnect its 
electrical connector from the PCBA. 

d)

  Remove the 3 nuts from item 6 by 

holding the pump down. 

e)

  To replace pump repeat steps a) 

through e) in reverse. 

 
 

3

4

5

2

1

6

Отзывы: