Quick Start - Setup Menus - Strobe Version (continued)
•
Pulse Width Limit
– set the maximum pulse width associated with the maximum peak
current. A low value is safest, but may not be seen if set too low (Typical range is 2 to
60,000us).
•
Strobe Minimum Period Limit
– set the minimum period for which external trigger pulses will
be allowed. A high value, ex. 60,000 microseconds, is safest (Typical range is 20 to
60,000us).
•
Trigger Source
– Used to determine Internal or External trigger source. A setting of Internal is
default.
•
Trigger Polarity
– Used to define the edge of the trigger pulse the system fires from. Rising
edge is default, which is typical for most users.
Metaphase LED Light Engine
Model#: MP
-
LE1007
Trigger Polarity
Chan 1 Rising
Trigger: Intern
Chan 1
MinTrgPer: 1000us
Chan 1
MaxPulsW: 200us
Chan 1