 Never remove the battery pack yourself. Wrong battery cells in combination with the charger can

  cause fire and injuries.

   

General:

- After each dive, rinse the dive lamp under running water to remove all traces of sand and salt.

- Avoid physical impact.

- Avoid overheating and direct exposure to sunlight.

-  

 When the batteries are almost empty the light will switch off automatically. Tthe batteries shoud be

    charged a.s.a.p.! Uncharged storage will cause deep discharge.

(Only  XRE500R)

 In this case the batteries can’t be charged anymore!

INSTRUCTIONS  FOR  USE

Warning:

Remarks:

-  

When you don't use the light for a long time (more than 6 months) it should be fully charged.

Changing the rechargeable battery pack (XRE500R)

- For changing the battery pack we recommend the light is hand in at an authorized Metalsub dealer.

Warning:

Switching the light on and off

Flash:

    Press the switch from the 

dim 

position

 (dim 25%)

 

1 x fast (within 1 sec.)

S.O.S:

    Press the switch from the 

1 x fast (within 1 sec.)

flash 

position

 

The S.O.S. flash should only to be used in case of an emergency.
From  S.O.S. position to on (100%):

 Press the switch from the S.O.S.

 

position

 

1 x fast (within 1 sec.)

Signal- / Dim options

pressure switch

Dim (50%) capacity:

    Press the switch from the 

on

 position 

1 x fast (within 1 sec.)

On:

   Press the switch during 2 secons from the off position. The light will burn at 100% capacity.

Off:

   Press the switch during 3 seconds. The light will blink several times and switches off afterwards.

Dim (25%) capacity

    Press the switch from the 

dim

 position (

dim 50%

1 x fast (within 1 sec.)

Changing the batteries  (XRE500Standard)

 

Take off the empty batteries from the holder and pull new batteries in the holder.
The new batteries shoud be placed in the correct posistion in the holder.
The polarity is indicated in the holder..

Warning: Only use LR06 - AA
                              Alkaline batteries

Check and rinse 

Turn the screw on the back side of the lamp to the left.  Pull off the battery holder

the O-ring on the back side of the screw and grease it with silicone grease

before replacing the screw. 

SAFETY PRECAUTIONS!

-

Read this manual carefully before using the dive light.

-

Always carry a backup light in case of dangerous dives 

-

Prior to air travel the battery pack (XRE500R) must be discharged entirely. Unscrew the 

     lamp head from the housing  (to prevent  overheating if the lamp should be switched on by 
     accidental impact or mishandling). 

(XRE500: remove the batteries.

-

To prevent loss always clip or tie the lamp to the B.C. with a Lanyard.

-

Always use the supplied charger MP400 

-

Always charge the lamp in a dry and well ventilated place with an ambient temperature 
between 0  and 30°C and never by open fire 

(XRE500 Rechargeable).

(XRE500 Rechargeable).

Always use the charger that is delivered with the dive light. 
The use of other chargers can damage the battery cells inside!

We advise  to use the dive light only underwater. If the dive light should be used above water it is advisable to use only 
the dim positions.

Charging the battery pack 

Turn the screw on the back side of the lamp to the left

connect the charger to a 220 Volt mains.

The charger is suitable for mains between 100-240 Volts.
The charger is fitted with a Delta-V charge controller, when the battery pack 
is full de charger will automatically switch over to trickle charging

first disconnect the power supply cord from the mains.

After that disconnect the plug from the charging socket

inse the O-ring and apply a thin coating of silicone grease before 

replacing the screw. 

 (XRE500R)

(LED burns green).

When the battery pack is full 

.  

Check and r

Securely insert the charger plug into the charging socket on the back of the dive light
(see fig.) Then 

Before the first use, the battery pack inside the dive light must be charged
completely. Please wait until the LED light on the back of the dive light starts 
flashing green before you disconnect the charger, this will extend the life
span of the battery pack.

Do not leave the dive light permanently (several days) on trickle charge. 