5 Safety
5.1 CE homologation mark
This appliance has been tested according to directive 2009/142/EC and on the basis of standard EN509.
It concerns an ornamental gas-fired open fireplace intended for ambiance heating.
5.2 Safety instructions for the installation
This open gas appliance may only be installed by a recognized installer according to the applicable national
and/or local regulations.
Prior to the installation, check whether the gas supply (type of gas and gas pressure) correspond to the
appliance’s configuration . These data can be found on the name plate.
It is not allowed to place in the combustion compartment other objects than the factory-supplied ceramic log sets
and ornamental material.
Take the necessary precautions that no overheating occurs of elements in the immediate vicinity of the appliance
(curtains, floor, walls, etc.) by using incombustible material.
All safety functions installed in the appliance may not be bridged, modified or disabled.
In case the flame protection of the appliance is activated deliberately or accidentally, or in case the thermostatic
draught safety device is activated so that the fire dies, you must wait for 3 minutes before lighting the fireplace
again.
The fireplace must be checked for any leaks of the gas connection and flue gas duct.
5.3 Safety instructions for the user
An open gas-fired fireplace is intended for ambiance heating, and therefore cannot be considered being main
heating.
The fireplace’s screen does not provide full protection for small children, elderly people and disabled persons. It is
recommended to provide for additional protection.
Ensure that inflammable materials (wood trimmings, curtains, inflammable liquids, furniture) both over and around
the fireplace are at a minimum distance of 1 m from the fireplace.
All visible parts of the fireplace after it has been built-in must be considered being active heating surface, and
therefore cannot be touched when the fireplace is burning. These parts pose a risk of burns.
5.4 Safety devices on the fireplace
On all fireplaces models, a safety device is provided so that the fireplace cannot be started in case the flue gas
valve and the fresh air supply valves are not fully opened. All fireplace models are fitted with a pilot light with
ionization measurement in order to bring about flame detection. In case the pilot light is not correctly detected, the
fireplace will immediately be switched off and enter an error cycle (red LED on the infrared receiver).
B11AS configuration:
Execution with natural draught and atmospheric protection. The pilot light is fitted with an
atmospheric protection device so that in case smoke reflux would occur due to a draught problem in the chimney,
the fireplace is switched off before the CO level in the room would reach a dangerous level (maximum 200ppm)
B11BS configuration:
Execution with natural draught and thermostatic smoke reflux protection. In case smoke
reflux would occur slag due to a draught problem in the chimney, this will be detected by means of a
thermocouple (TTB) (TTB: Thermal flue gas non-return blocking device)
at the fireplace’s opening, and the
fireplace is switched off.
B14AS configuration:
Execution with flue gas fan with underpressure monitoring and atmospheric protection. In
case the draught in the chimney (underpressure) becomes insufficient, the underpressure sensor integrated in the
flue gas fan switches off the fireplace. There is also the atmospheric pilot light protection device that switch off the
fireplace before the CO level in the room reaches a dangerous level. (maximum 200ppm)
B14BS configuration:
Execution with flue gas fan with underpressure monitoring and and thermostatic smoke
reflux protection. In case the draught in the chimney (underpressure) becomes insufficient, the underpressure
sensor integrated in the flue gas fan switches off the fireplace. There is also a thermocouple above the fireplace’s
opening that will detect smoke reflux, if any, and thus switches off the fireplace.