background image

5

 

 

 

 

Pict. 3

Connection and installation measures:
TYPE   

        MC 8 N 

 

 

MC 8 P

 A(mm)      

           396 

 

 

   396

 B(mm)      

           287 

 

 

      -

 C(mm)      

           274 

 

 

   274

 D(mm)      

           266 

 

 

   266

 E(mm)       

              - 

 

 

   151

 F(mm)     

           140 

 

 

   140

CONNECTION TO WATER SUPPLY

 

Input for cold water on the water heater  is marked with blue 

ring  while  hot  water  output  is  marked  with  a  red  ring,  which  is  to 

be  respected  when  connecting  water  heater  to  water  supply.   The 

models marked N are for installation above the fitting (pipe), while 

P models are for installation below fitting (pipe)  - see Picture 2 Low 

capacity water heater works without pressure (open system) and it is 

possible to use water only at one spot in the house.

 

The fittigns/mixing pipes appropriate for work without pres-

sure have to be used with this water heater – water inlet into the fit-

ting not over 3-4 mm diameter, and for low installation models, the 

fitting should have 3 pipes. On the inlet pipe before the mixing unit 

a non-return valve should be mounted to prevent tank to empty in 

case of pressure fall in water supply pipeline. 

Содержание INOX MC8N

Страница 1: ...INSTRUCTIONSFORINSTALLATION USEAND CARE OFWATERHEATERS INOX MC8N MC8P...

Страница 2: ...2 CONTENTS TECHNICAL INFORMATION 3 INSTALLATION 3 CONNECTION TO WATER SUPPLY 5 STEPS FOR CONNECTION TO WATER SUPPLY 6 CONNECTION TO POWER SUPPLY 7 USE AND MAINTENACE 7 WASTEDISPOSAL 8...

Страница 3: ...sticker Table with Characteristics between con nection pipes Picture 1 shows the water heater with all components N wall high installation P low installatiuon INSTALLATION Only authorized persons are...

Страница 4: ...t water can be used only in one place Technical characteristics of low capacity water heater Type MC 8 N MC 8 P Capacity litres 8 Nominal pressure Mpa 0 Heater power W 1500 Voltage 230 Time of water h...

Страница 5: ...bove the fitting pipe while P models are for installation below fitting pipe see Picture 2 Low capacity water heater works without pressure open system and it is possible to use water only at one spot...

Страница 6: ...the water heater at desired place near the fitting For P ver sion the installation is made below the fitting and for N version above the fitting see picture 2 2 Connect the water heater and fitting us...

Страница 7: ...er heater it must be unplugged from the power supply USE AND CARE Switch on the heating of water by turning the button of the regulator to a certain position depending on desired temperature Maximum w...

Страница 8: ...ing pipe First filling and heating should be monitored till the moment the signal lamp goes off WASTE DISPOSAL WHAT AFTER YOUR WATER HEATER IS NO MORE USABLE The accumulation water heaters and the pac...