4
When this valve is powered on, the air supply is enabled.
When the power supply is switched off, the compressed air supply
is cut off and air downstream is relieved.
The valve can also be opened without powering it on by pressing
the test button. This is a monostable button which returns to the
closed position when released.
NB:
If there is also a manual V3V valve, the air supply is only
enabled if it is in the On position.
FILTER
PRESSURE REGULATION
V3V MANUAL VALVE
NO
YES
8
ON
OFF
1
2
V3V ELECTRIC VALVE
The filter cartridge is positioned horizontally. To replace it, merely
unscrew the plug on the front. The unit contains an automatic
on-off valve, so the valve closes automatically when you remove
the plug. There is no need for a tap upstream and there is no
risk of the plug being blown out.
Considering that the air in the cartridge flows outwards, the dirt
collects inside the cartridge and does not affect the other internal
surfaces.
It is always advisable, however, to clean the inside of the unit and
the plug.
When you replace the plug, tighten it to a maximum torque of
6 Nm
, taking care not to damage it. Use an 8-mm Allen wrench
if necessary.
1-
Turn the knob until you read the desired value on the gauge
2-
Then press the knob to lock it.
Controlled air relief is provided to improve the pressure regulation.
NB:
The pressure in standard regulators must always be set
upwards.
When the valve is in the On position, the air supply is enabled.
When the valve is in the off position, the air supply is shut off and
the air downstream is discharged.
If the V3V valve is the padlock type, you can attach the padlock
when the valve is on OFF to present it from being rotated.
NB:
If there is also an electric V3V or APR, the air supply is only
enabled if the power supply is on.
5 μm (yellow)
20 μm (white)