FLUX 0

 50 L

FLUX 0

 200 L

Measured flow range

Nl/min

0 - 50

0 - 200

Direction of flow

Unidirectional

Working pressure range

bar

-0.9 to 8

MPa

-0.09 to 0.8

psi

-13 to 116

Maximum admissible pressure

bar

10

Pipe diameter for push-in fitting

mm

8

Connecting cable

VDC

12 to 24 ± 10%, ripple max 10% 

Current consumption

mA

≤ 50

Power cable

Cable Ø 4 length 2 m, oil resistant, 26 AGW (6 x 0.15 mm

2

)

Weight

g

100 (including cable)

DISPLAY

lnstant flow rate 

Display range

Nl/min

0 - 50

0 - 200

Minimum setting scale

Nl/min

0.1

1

ft

3

/min

1

1

Cumulative flow rate 

Display range

9999999.9

99999999

Minimum setting scale

Nl 

0.1

1

ft

3

1

1

Pressure

Display range

kPa

-100 to 1000

Minimum setting scale

kPa

1

bar

0.01

psi

0.1

PRECISION

Flow rate

Guaranteed measuring range

2 to 100 % FS

Display accuracy

± 3 % FS  ± 1 digit 

s

Analogue output accuracy

± 5 % FS 

s

Repeatability

± 1 % FS  ± 1 digit 

n

Linearity

± 3 % FS 

n

Temperature characteristic

± 2 % FS for a temperature range of 15-35°C; ± 5 % FS for a temperature range of 0-15°C or 35-50°C 

n

Pressure characteristic 

± 5 % FS  ± 1 digit 

Pressure

Guaranteed measuring range

0 to 100 % FS

Display accuracy

± 2 % FS  ± 1 digit 

Analogue output accuracy

± 2.5 % FS 

Repeatability

± 0.2 % FS  ± 1 digit 

Linearity

± 1 % FS 

Temperature characteristic 

± 2 % FS 

DIGITAL OUTPUTS

N ° outputs

2 PNP

Max current

mA

125

Max voltage

VDC

24

Residual voltage

V

≤ 1.5 V

Response time, with flow rate setting

ms

50, 80, 120, 200, 400, 800, 1500 (default 800)

Response time, with pressure setting

ms

2.5, 25, 100, 250, 500, 1000, 1500 (default 2.5)

Response mode, with flow rate setting

Hysteresis mode, window comparison mode, cumulative mode, cumulative pulse mode

Normally open or normally closed

Response mode, with pressure mode setting

One-point setting mode, hysteresis mode, window comparison mode. Normally open or normally closed

Hysteresis

Adjustable

Short-circuit protection at output

Yes

Cumulative pulse output

Nl/impulse

0.5

2

ft

3

/impulse

2

7

s

  Data valid under these conditions: input pressure 3 bar, output pressure 1 bar, temperature 25°C

n

  Data valid under these conditions: output pressure 1 bar, temperature 25°C

  Data valid under these conditions: -90 to 800 kPa, output pressure 1 bar, temperature 25°C

  Data valid under these conditions: flow rate 0 Nl/min, temperature 25°C

4. TECHNICAL DATA

Содержание FLUX 0

Страница 1: ...FLUX 0 DIGITAL FLOWMETER AND PRESSURE SENSOR USER MANUAL...

Страница 2: ...2...

Страница 3: ...oad meets the following formula Power Supply Internal voltage Minimum operating voltage drop of sensor voltage of load Do not operate the product outside the specifications The sensor will be damaged...

Страница 4: ...tighten will damage the product Do not mount the sensor in a place that will be used as a foothold The product may damage if sit or step on it accidentally When mounting without a bracket please use...

Страница 5: ...range of catalog or and not following the instruction manual The sensing element cannot measure properly if foreign matter adheres to it On the inlet side be sure to install an air filter below the fi...

Страница 6: ...6...

Страница 7: ...rd selection PAGE 26 2 3 8 F 08 Analog output selection PAGE 27 2 3 9 F 09 Accumulated value hold selection PAGE 28 2 3 10 F 10 Flow sensor display mode selection PAGE 29 2 3 11 F 91 Power save mode s...

Страница 8: ...alfunction or damage to the product Piping for the One Touch Fitting insert the tube firmly into the fitting and make sure it cannot be pulled out Also using the proper tube cutter is recommended to e...

Страница 9: ...rizontally or vertically but the flow rates may change because of the installation way of the product or piping The tightening torque for screws should be under 0 5 0 1 N m 1 Horizontal mounting by Th...

Страница 10: ...ite Output 2 Yellow External input Yellow External input Orange Analog output Orange Analog output 1 2 3 4 5 6 1k 1 3 Wiring Diagrams 1 3 1 PNP Output Analog Output and External Input Brown Orange Yel...

Страница 11: ...ort Inlet side Output 1 Indicator 3 Color LCD Display Flow Symbol Flow Display Button Button Analog Signal Indicator Output 2 Indicator Output 1 Indicator Output 2 Indicator Analog Signal Indicator Pr...

Страница 12: ...Select the flow value is shown under standard ANR or normal condition NOR Select the analog corresponding to pressure or flow sensor To save the last accumulated flow value every 2 or 5 minutes Select...

Страница 13: ...o display F 01 Press or button to select other setting functions Press for 3 sec at Function Setting Mode to return to Measurement Mode 2 3 Operation Instructions Function Selection Mode Ag kPa L min...

Страница 14: ...r of OUT1 Flow sensor Ag kPa L min Selected Output Sensor Pressure sensor Press button to be continued Ag kPa L min Output Mode Setting Select output mode Press or button to select output mode of OUT1...

Страница 15: ...t Value Setting Out1 set value setting Press or button to adjust the set value Hysteresis Mode HYS FL 1 FH 1 Window Comparator Mode FL 1 FH 1 Accumlated Output Mode ADD AddL AddH NOTE Set value settin...

Страница 16: ...ng Select output mode Press or button to select output mode of OUT1 Hysteresis Mode Ag kPa L min Window Comparator Mode One Point Set Mode Ag kPa L min Ag kPa L min Ag kPa L min Press button Ag kPa L...

Страница 17: ...ust the set value Hysteresis Mode HYS L 1 H 1 Window Comparator Mode L 1 H 1 One Point Set Mode oPS P 1 Ag kPa L min Fixed Hysteresis Setting Fixed hysteresis setting Press or button to adjust fixed h...

Страница 18: ...L 2 L 1 L 2 FH 1 FH 2 H 1 H 2 P 1 P 2 Time AdH1 AdL1 AdH2 AdL2 Pressure Flow NOTE 1 In case hysteresis is set at less than or equal to 2 digits switch output may chatter if input pressure fluctuates n...

Страница 19: ...l How to Use 2 3 2 F 02 OUT2 Setting Selection Setting corresponding sensor and operating mode of OUT2 1 Press or button at function setting mode to start OUT 2 Setting F 02 oUt2 2 Check the F 01 for...

Страница 20: ...r button to select color display for OUT1 or OUT2 Display color of OUT1 Ag kPa L min Display color of OUT2 Display Color Mode Selection Press the or button to select Display Color Mode ON Green OFF Re...

Страница 21: ...onse Time Selected Sensor Ag kPa L min Ag kPa L min 2 3 4 F 04 Response Time Selection Select proper response time to avoid switch output chattering Press or button at Function Selection Mode to displ...

Страница 22: ...sensor Ag kPa L min Pressure sensor Response Time Selection 2 5ms 25ms 1500ms Ag kPa L min Selected Sensor Set Value Ag kPa L min Ag kPa L min Ag kPa L min Setting response time of pressure sensor Pr...

Страница 23: ...the proper display refresh time to reduce frequently changing value Press or button at Function Selection Mode to display F 05 UPdA 1 Flow sensor setting Setting refresh time of flow sensor Press or b...

Страница 24: ...pressure sensor Flow sensor Pressure sensor Ag kPa L min Display Refresh Time Setting Set Value Refresh Time Ag kPa L min Setting refresh time of pressure sensor Press or button to select refresh time...

Страница 25: ...10 2 Ag kPa L min Ag kPa L min Ag kPa ft3 min Pressure Unit Selection Press or button to select pressure unit Ag kPa L min Ag kPa L min Ag kgf cm2 L min Ag bar L min Ag psi L min Set Unit Pressure Se...

Страница 26: ...erence Standard Selection Press or button to select the standard or normal condition Standard conditon ANR Normal condition NOR Ag kPa L min Ag kPa L min Ag kPa L min Flow Reference Selected Condition...

Страница 27: ...or pressure sensor Operation Press or button at Function Selection Mode to display F 08 AnG Sensor Selection Press or button to select the sensor of analog output Flow sensor Pressure sensor Ag kPa L...

Страница 28: ...he memory device is 1 million cycles If the sensor is operated 24 hours per day the durability is calculated as below 5 minutes x 1 million cycles 5 million minutes 9 5 years 2 minutes x 1 million cyc...

Страница 29: ...button at Function Selection Mode to display F 10 DiS Display Mode Selection Press or button to select display mode Instantaneous Flow Mode Accumulated Flow Mode Ag kPa L min Ag kPa L min Ag L Ag kPa...

Страница 30: ...ons is pressed in 30 sec press any keys to leave the Power Save Mode Operation Press or button at Function Selection Mode to display F 91 ECo Power Save Mode Selection Press or button to turn on the p...

Страница 31: ...ed The switch output function operates relative to its change This function is only for output 1 corresponding to flow sensor action point When external signal is input please connect the input wire t...

Страница 32: ...djust flow and pressure display values Display values can be calibrated to within 2 5 R D Press or button at Function Selection Mode to display F 94 FinE 1 Fine adjustment of instantaneous flow value...

Страница 33: ...ure value Ag kPa L min Ag kPa L min Ag kPa L min Ag kPa L min Fine Adjustment of Pressure Value Fine adjustment of pressure value Press or button to setting fine adjustment of display value Ag kPa L m...

Страница 34: ...Press or button to setting OUT1 OUT1 OFF OUT1 ON Ag kPa L min Ag kPa L min Ag OUT1 kPa L min Set Value Output 1 Ag kPa L min OUT2 setting Press or button to setting OUT2 OUT2 OFF OUT2 ON Ag kPa L min...

Страница 35: ...y default settings can be restored Operation Press or button at Function Selection Mode to display F 99 rESt Reset to The Default Setting Press or button to return to the factory default setting Disab...

Страница 36: ...ro point at the time of shipment from the factory Operation Press and button simultaneously over 3 sec at the measurement mode not Accumulated flow value display mode until display 00 And release hold...

Страница 37: ...he zero point at the time of shipment from the factory Operation Press and button simultaneously over 3 sec at the measurement mode not Accumulated flow value display mode until display 00 And release...

Страница 38: ...alue return to zero Operation Press and button simultaneously over 3 sec at the measurement mode Accumulated flow value mode until display zero And release holding the button to return measurement mod...

Страница 39: ...when the power was supplied to this moment is detected and updated Operation Press button over 3 sec at the measurement mode The maximum value will be displayed flashing and is held Press button retu...

Страница 40: ...m when the power was supplied to this moment is detected and updated Operation Press button over 3 sec at the measurement mode The minimum value will be displayed flashing and is held Press button ret...

Страница 41: ...while the key lock setting is ON LoC on is displayed for 1 sec Operation Press button over 5 sec at measurement mode to select key lock unlock setting Key Lock Unlock Setting Press or button to select...

Страница 42: ...no pressure conditions Reduce the flow to the display range Reduce the pressure to the display range Ensure the flow is in the correct direction Reduce the pressure to the display range Output 2 load...

Страница 43: ...5 FS 1 digit Pressure Guaranteed measuring range 0 to 100 FS Display accuracy 2 FS 1 digit Analogue output accuracy 2 5 FS Repeatability 0 2 FS 1 digit Linearity 1 FS Temperature characteristic 2 FS...

Страница 44: ...re Sensor 2 Temperature Sensor 1 Heating Element Temperature Sensor 2 Temperature Sensor 1 Heating Element Temperature Sensor 2 5 THERMAL MASS FLOW SENSOR PRINCIPLES FLUX 0 50 L FLUX 0 200 L ANALOGUE...

Страница 45: ...CONSTRUCTION Case PC ABS Liquid crystal cover PC Electronic circuit board Port Filter Stainless Steel Resin Body PBT O ring NBR Sensor Noryl Button Silicone Liquid crystal One Touch Fitting 6 DIMENSI...

Страница 46: ...46 www metalwork eu ZVAVA9007 EN IM01_07 2020 NOTES...

Отзывы: