13.

DYNAMIC 2500 & 3500

GENERAL MAINTENANCE & INFORMATION

(IMPORTANT: READ THIS PAGE)

FIRE  BRICKS: 

The  fire  bricks  are  made  of  high  grade  refractory  mortar  which  will  give  good  life  if 

maintained by rendering periodically with fire cement.

SURFACE FINISH:

 Due to the hard working nature and high temperature of the boiler the painted surface 

will wear with use. This is normal and will need to be retouched from time to time.

To clean wipe with a damp cloth. When stains become unsightly repaint affected area. The boilers surface 

will need to be cool and clean. Remove any loose material.

The new paint will cure and harden when the boiler reaches good working temperatures.

WARNING:

 Consult  a  qualified  installer  in  regards  to  the  installation  of  any  hydronic  central  heating 

system. Failure to do so could result in injury to person or property.

OPERATING HINTS

*  Always open damper control on boiler before refuelling.

*  Rake  grate  and  clean  ashpan  out  regularly.  (Ash  rake  and  combined  spin  wheel  and  ashpan  tool 

provided).

*  Avoid wet or green wood – these will cause maintenance problems in any stove or boiler.

*  Briquettes or coal may be used and will give good overnight operating temperatures.

*  Check and clean flues and smokeways at least every 12 months.

*  A  hot  fire  burning  slowly  produces  little  or  no  smoke.  A  cold  fire  smouldering  produces  maximum 

smoke.

*  Condensation may form in the fire box or ashpan area when the boiler is first lit or is cold. This will 

evaporate as the boiler warms. The condensation may be quite pronounced.

**  Check rust inhibitor every 6 months or after any major boiling or water loss. The boiler is 

made of mild steel and will give years of trouble free operation providing anti-rust and if 

required  hardness  conditioner  levels  are  maintained.  If  water  supply  is  acidic  add  sodium 

bicarbonate (cooking soda) - ask your dealer.

Thermalux “Thermablend” long life rust inhibitor available from the manufacturer or dealer.

WARNING

HYDRONIC CENTRAL HEATING 

(IMPORTANT: READ THIS PAGE)

For information on or the supply and installation of  Hydronic Central Heating components to suit your 

home and your requirements, and to ensure you comply with relevant building requirements, consult your 

local Thermalux dealer or a qualified, experienced installer.

Failure to correctly install a Hydronic Central Heating System could result in injury to person or property.

Happy Heating from all at Thermalux.

Manufacturers of High Quality Solid Fuel Appliances

Содержание CD series

Страница 1: ......

Страница 2: ......

Страница 3: ...ZS 7421 1990 AND THE APPROPRIATE REQUIREMENTS OF THE LOCAL BUILDING REGULATORY AUTHORITY MIXING OF APPLIANCE OR FLUE SYSTEM COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING THE DIMENSIONAL SPECIFICATION...

Страница 4: ...ue may be required We recommend the flue extend to the top of the chimney and a chimney cap and cowl be fitted This is now law in most areas Free Standing Installation A 150mm diameter flue of at leas...

Страница 5: ...general indication of the oven temperature however it may tend to read lower than the actual oven temperature as the thermometer is positioned in the coolest part of the oven The oven thermometer has...

Страница 6: ...ilure to read the following instructions could result in an incorrect installation or use and may void warranty Please read section on running the stove very carefully C D MODELS Check Thermablend lon...

Страница 7: ...ht in conjunction with the firebox air controls to achieve longer overnight burn times however in many installations the use of the Dilution control is not required Solid Oven Tray The solid oven tray...

Страница 8: ...ea towels drying on the rail should not be left in front of the firebox door Fuel should be stored safely and the stove should not be left unattended if full of fuel and air controls fully opened 6 Ma...

Страница 9: ...ion situations Set and light the fire as per earlier instructions Have all three spin wheels open and flue damper control open As fire becomes established close spin wheels from top to bottom ie close...

Страница 10: ...g instructions could result in an incorrect installation or use and may void warranty Please read section on running the stove very carefully C D MODELS Check Thermablend long life rust inhibitor and...

Страница 11: ...ften When cooking roast or cakes which need extended cooking times remove solid oven tray and place in a cool spot 20 to 30 minutes into cooking procedure slide cool tray onto top oven shelf position...

Страница 12: ...heating cooker Hydronic Central Heating is the most wonderful form of home heating To achieve the best results you should think of your cooker as a heater You may need to refuel your CD more frequent...

Страница 13: ...lure to read the following instructions could result in an incorrect installation or use and may void warranty Please read section on running in the stove very carefully Check Thermablend long life ru...

Страница 14: ...ation to installation DYNAMIC 3500 BOILER DANGER The Dynamic 3500 Boiler must be open vented to prevent the system becoming pressured consult a qualified installer The operation of the Dynamic 3500 Bo...

Страница 15: ...sed and will give good overnight operating temperatures Check and clean flues and smokeways at least every 12 months A hot fire burning slowly produces little or no smoke A cold fire smouldering produ...

Страница 16: ...gs all of which require normal service to maintain them Under the terms of this Warranty Metal Dynamics assumes no responsibility for the labour costs involved in removing or replacing the stove nor s...

Страница 17: ...han one item if applicable WHY DID YOU CHOOSE THERMALUX 1 Reason for choice 100 Australian Product Price Solid Construction Appearance Recommendation of Friend Recommendation of Dealer Choice of Model...

Страница 18: ...16...

Страница 19: ......

Страница 20: ......

Отзывы: