50.5-9800 Rev C
Page 13
4. MAINTENANCE AND TROUBLESHOOTING
The 50.5 Sensor is sealed and there are no replaceable parts contained within. The 50.5 does
not require periodic calibration and there are no internal adjustments that can be made.
4.1. GENERAL MAINTENANCE SCHEDULE*
12-24 month intervals:
A.
The Model 50.5 Wind Sensor should be inspected periodically for physical damage to the
sensor arm assembly and cable connections. Inspect all transducers to make sure that
they are securely fastened.
*Schedule is based on average to adverse environments.
4.2. TROUBLESHOOTING
Symptom
Probable Cause
Action to Repair
Wind Speed output goes to
maximum value.
Blocked pathway (single),
Failure in transducer or
electronics. Bent or damaged
sensor array.
Check path and clear. Return
sensor for service if clear.
Wind Speed output very high,
but not maximum value.
Both pathways blocked,
Failure in two transducers,
Bent or damaged sensor
array.
Check path and clear, return
sensor for service if clear.