background image

CCS MODEM-9800 Manual Rev A 

Page 4 

 

1  INTRODUCTION 

 

 

About the Comet Cloud Service (CCS) Modem  

The Met One Instruments, Inc. Comet Cloud Service (CCS) modem provides real time remote 
connectivity to a range of Met One particulate and weather sensors.  The CCS package includes 
the cellular modem hardware, a personalized webpage dashboard, and 1 year of free cellular and 
cloud website data hosting services. 

The CCS web dashboard gives current measurement values graphically and in tabular form; the 
private link can be shared with other authorized users allowing easy data sharing across an 
organization.  Data is stored in the cloud for 2+ years, and can be downloaded to a computer or 
other device at any time. 

The CCS modem uses Met One’s standard communication protocol to identify and setup any 
connected compatible device.  Dual quick-connect connectors are included and allow up to 2 
sensors devices, such as an NPM Sensor particulate monitor and an AIO 2 weather sensor, to 
share one common modem and website.  Alternatively a single device with a datalogger such as 
the Automet 580 or E-BAM particulate monitor can be connected. 

 

 

Comet Cloud Service Modem Specifications 

 
 

Parameter 

Specification 

Power: 

Input: 12 VDC 

Power Consumption: 

110 mA Average Draw  

Operating Temperature: 

-25

 to +60°C / -13

 to +140

 F 

Ambient Humidity Range: 

0 to 100% RH, non-condensing. 

Mounting: 

Pole mounting bracket with hose clamps. 

Unit Weight: 

0.95 kg / 2.1 lb.  

Unit Dimensions: 

36.7 X 11.5 cm / 14.5 X 4.5 in (H X DIA.) 

Rating: 

IP64 

GPS: 

Internal GPS module included 

I/O Interface: 

MOI 7500 Protocol, via RS-485 or RS-232 

Network Compatibility: 

LTE-M (U.S. Domestic) GSM (Internationally w/ over 550 networks) 

Data Collection on Modem: 

Every 1 Second 

Data Update Rate To Cloud: 

Standard: USA: 15 Minute – Optional: USA 5 Minute 

Standard: Global: 60 Minute – Optional: Global 15 Minute 

Data Storage on Cloud: 

2 Years (oldest data overwritten after that) 

Data Plan: 

1 year of Service included with purchase of CCS Modem 

Renewals available from Met One Instruments, Inc. Service Department. 

 

Specifications may be subject to change without notice

Содержание CCS MODEM 2

Страница 1: ...1 Met One Instruments Inc Corporate Sales Service 1600 NW Washington Blvd Grants Pass OR 97526 Tel 541 471 7111 Fax 541 471 7116 www metone com www service metone com COMET CLOUD SERVICE MODEM MANUAL...

Страница 2: ...n installation setup and field calibrations Other sections that provide in depth information on subjects such as theory diagnostics accessories and alternate settings provide valuable information whic...

Страница 3: ...CS Modem 5 Components 5 Installing the CCS Modem 6 Connect Sensors to the CCS Modem 6 Powering on the Device 7 3 Downloading and Viewing the Data 8 Comet Software 8 3 1 1 Cloud Service Webpage 8 3 1 2...

Страница 4: ...tor and an AIO 2 weather sensor to share one common modem and website Alternatively a single device with a datalogger such as the Automet 580 or E BAM particulate monitor can be connected Comet Cloud...

Страница 5: ...the shipment is noticed before unpacking a claim must be filed with the commercial carrier immediately You should follow any special unpacking instructions provided by the carrier as you then carefull...

Страница 6: ...bstructed view of the sky Mount sensor s to be connected with CCS Modem in accordance with each product s installation documentation Connect Sensors to the CCS Modem The CCS Modem can collect and repo...

Страница 7: ...you wish to connect an existing monitor to the CCS MODEM Connect the appropriate sensor cable s to each sensor and to the CCS Modem s communication ports CCS Bottom Connector Plate Powering on the Dev...

Страница 8: ...ws the user to connect to the cloud and download the data from each CCS cloud service webpage The Comet CD also contains a very comprehensive pdf user s manual for the program Insert the CD and instal...

Страница 9: ...D into your PC and the install program should run automatically as shown in the image below If an AutoPlay pop up window appears select Run AutoRun exe Select Install Comet to begin the installation p...

Страница 10: ...lugin from the drop down menu Users will then need to enter their API key and device serial number in order to authorize the access to the device s data Press OK to save your station Note Customers wi...

Страница 11: ...1 Comet will then connect to the cloud site and download the device s data Users can then use the data tab and chart tab to visually look at the data When Comet downloads the data a CSV file is create...

Страница 12: ...e Cloud Works The CCS uses a cloud service for storing and viewing data from the connected sensors After the CCS collects the data from the connected sensors it connects to the internet and designated...

Страница 13: ...includes one year of cellular data and website hosting at no extra charge The cloud service can be renewed by contacting the Met One Service department at service metone com or 541 471 7111 The follo...

Отзывы: