Intelligent setting 

PM2.5 sensor is built-in. It checks the dust or particles 

and display it by data.  

 

The air quality indicator will be lighted after pressing the 

“Auto” button. The machine checks the air quality and 

control its working status automatically. 
 

 

Best 

 

Good 

 

Mild-to-moderate polluted 

 

Worst polluted

 

 
 

Remarks: 
-

 

The quantity of the air quality indicator means air 

quality level and its working status. 

-

 

When  you  choose

  the  intelligent mode, the device 

will take 3 minutes to warm up, "Settings" icon is not 

operative in this mode. 

-

 

When air humidity is above 80%, it will affect the 

sensitivity of sensor, the PM2.5 data is just for your 

reference. 

 

 

PM2.5 abnormal performance correcting 

After using  the PM2.5 sensor for a long time, trace 

amounts of particulate will adhere to the sensor inductive 

head, it may cause the PM2.5 numerical display 

abnormal. 

When you find PM2.5 numerical severely deviated from 

the normal range, here we advise you collect it as follow 

steps 
based on the weather forecast's PM2.5 numerical in your 

city. 
1.

 

Open the window ventilated for 5 minutes (PM2.5 

sensor will re-collection current environmental data). 

2.

 

Long press "function" icon, after heard a "click", 

showing it antomatic switch to PM2.5 display 

window, then enter PM2.5 correcting mode. 

3.

 

Each time you press "function" icon, the machine's 

PM2.5 numerical will increase 2  ug/m

3

, each time 

you press "smart" icon, 

4.

 

PM2.5 numerical will decrease 2 

µ

g/m

3

5.

 

When  the  PM2.5 

numerical adjust to the PM2.5 

numerical of your city's weather forecast, waiting 5 

seconds, PM2.5 sensor collection finished.  
 

Filters life time reset

 

If he filter icons are always flashing, it means the filters 

life time comes to the end. Please clean or replace with 

new filters. 

 

After cleaning or replacing the filters, press “Reset” icon. 

Filter icons will stop flashing and the unit will start to 

record the filters using time. 
 
Remark: “Reset” icon has refresh function. PM2.5 data 

can be refreshed after pressing the “Reset” icon. 
 

 

Activated carbon

 

 

HEPA filter

 

 
 
 
 
 

Содержание 100512

Страница 1: ...Rev 10 09 2020 Ref 100512 ES 3 Manual original EN 8...

Страница 2: ...l de control Control panel Asa Handle Cubierta filtro Filter cover Entrada aire Air inlet Salida aire Air outlet Etiqueta Label Agujero cable alimentaci n Power cord hole Atenci n Retirar bolsa de los...

Страница 3: ...eaken the insulation even cause fire Take out the plug and clean it with dry cloth Please remove the plug from the socket if not using for a long period ATENCI N Mal uso puede causar heridas PROHIBIDO...

Страница 4: ...guraci n Caracter sticas t cnicas Detecci n inteligente de la calidad del aire sensor de part culas PM2 5 incorporado Panel de control t ctil muy c modo Pantalla digital PM2 5 temperatura humedad indi...

Страница 5: ...rario o antihorario de manera que quede firme Encendido Pulse el bot n POWER en el panel frontal El aparato entra en el estado de trabajo inicial Selecci n de funciones Pulsando el bot n Settings se a...

Страница 6: ...n al sensor inductivo lo que podr a causar errores Si observa una medici n muy desviada del rango normal le recomendamos que tome como referencia el valor PM2 5 ofrecido por los servicios meteorol gi...

Страница 7: ...parato a otra habitaci n para volver a probar Peque os cambios del dato de humedad o temperatura Se est utilizando el aparato en un rea demasiado grande Utilice el aparato en una habitaci n con el tam...

Страница 8: ...e insulation even cause fire Take out the plug and clean it with dry cloth Please remove the plug from the socket if not using for a long period ATTENTION Misusing may cause hurt FORBID Do not power t...

Страница 9: ...iguration Technical features Air quality intelligent detection built in PM2 5 particle sensor Convenient control Digital display PM2 5 temperature humidity timer indicator intuitive and easy to unders...

Страница 10: ...OWER icon on the product operating panel machine is entered the initial working status Function setting Press the Settings icon on the product operating panel The anions UV lamp and ozone can be chose...

Страница 11: ...ed from the normal range here we advise you collect it as follow steps based on the weather forecast s PM2 5 numerical in your city 1 Open the window ventilated for 5 minutes PM2 5 sensor will re coll...

Страница 12: ...e move the machine to another room to test again Small changes for humidity or temperature data Is the machine using area too big Please use this machine in applicable room If the problem still existe...

Страница 13: ...Your trusted brand Talleres Mestraitua S L Txori erri Etorbidea 60 T 34 944530388 F 34 944711725 mestra mestra es www mestra es 48150 SONDIKA BILBAO ESPA A...

Отзывы: