Mestek WT-58DL Скачать руководство пользователя страница 5

a)

 

Power on the transmitter, the power indicator lights up, and the transmitter 

starts to work. 

b)

 

Connect one end of the cable to be tested to corresponding port (i.e. RJ45, 

RJ11) of the transmitter or connect to the RJ11 port via adapter.  

c)

 

Press the hunting function key (    ) of the transmitter, the transmitter starts 

to send digital signals to the cable to be tested. 

d)

 

Power on the receiver, the power indicator lights up, and the receiver starts 

to work. Press the hunting function key (    ) of the receiver, the receiver 

starts to receive digital signals in the cable.  

e)

 

Hold the receiver in hands, and detect at the other end (such as the 

surrounding of stacks of telephone line distribution cabinet, junction box, 

hub, switch etc.) of the cable to be tested. By comparing the sound sent by 

the receiver, and signal indicator strength, the cable sending out the loudest 

sound with the strongest signal indicator when getting close to the probe is 

the one in need.  

f)

 

During detection, the volume could be changed by adjusting the volume 

adjustment knob on the receiver, to adapt to the actual environment. 

g)

 

Use accessories with a clip to insert into RJ45 or RJ11 interface, and clamp 

the black clip onto the ground wire (i.e. water pipe, building grounding or 

equipment metal shell etc.) to increase the line  inspection distance. 

Note: When used in places subject to loud noise, use the headphone jack of the 

headphone receiver to help hunting.  

 

 

2.

 

Network cable alignment detection: 

Operation method: 

a)

 

Power  on  the  transmitter,  and  turn  on  the  power  indicator,  the  transmitter 

starts to work, and then press the alignment function button, the alignment 

indicator lights up.  

b)

 

Insert one end of the network cable onto the RJ45 socket of the transmitter.  

c)

 

Insert  the  other  end  of  the  network  cable  onto  the  RJ45  socket  of  the 

receiver. 

d)

 

System  starts  to  detect,  and  the  alignment  indicator  will  display  the 

detection result.  

e)

 

Long press the ( ) button for 2 seconds, the indicator lights up, and the red 

light  pen  emits  red  laser,  after  that,  insert  the  optical  fiber  connector  into 

the emission of the red light pen (only WT-58DL). 

 

3. 

Non-contact AC voltage detection (NCV) 

The NCV function could realize non-contact detection on live conductor with 

power frequency above 45V, when any AC voltage is detected, NCV indicator 

will behave according to different induced voltage strengths, the signal 

strength indicator will light up, and the receiver will make an alarm sound. 

Operation method: 

a)

 

Power on the receiver, the power indicator lights up, and the receiver starts 

to work. 

b)

 

Press the NCV key, the NCV indicator lights up, and close the inductive 

probe to the conductor or article to be tested. 

Отзывы: