Recharge batteries after use with the enclosed charger. To prevent a lazy

battery effect, discharge the devices every 5 times completely by using the
automatic switch off (Leave the system on, until it turns off automatically).

Afterwards, charge the devices as usual.

The devices have to be turned off before connecting to the charger. If this

is disregarded, the system might get damaged!

Figure 5.1 shows the pinning of the charge connector. Chargers have to be

connected to pin 2 (+) and pin 4 (GND). An external supply (6…8V, 0.5A)
can be connected to pin 3 (+) and pin 4 (GND). 

Use only power supplies

which are certified by mk-messtechnik.

 

The included chargers are not meant to power the transmitter or receiver 
during operation. The device outside the shielded room can be run with an
external power supply (optional). The internal device can be run with an 
external battery, if needed (optional). Do not use the external power 
supply or charger to power the device inside the shielded room while EMI-
tests are running. This might damage it!

Due to self-discharge issues with NiMH batteries, recharge batteries before
use, if the system has not been used for a longer time. 

Do not use cleaning agents or solvents to clean the devices, only use a
slightly moistened, soft cloth. 

Do not open the devices, as there are no parts inside which have to be
maintained. The opened housing can pose a fire hazard through short-

circuit currents! Please contact your distributor or the manufacturer if you
have   any   problems.   Send   in   the   complete   system   (both   devices),   if   a

problem cannot be solved by turning the devices off and on again or by
checking the positions of the switches. Please contact us in any case before

sending in the devices.

Maximum charging 
current is 1 A

Do not open the 
devices!
Short cut / fire 
hazard!

Figure 5.1: pinning of charge plug

Do not use charger 
or power supply 
during EMI-test!

Devices must be 
turned off before 
connecting to 
charger, or else the 
system might get 
damaged!

Pinning of charge- / 
buffer connector

Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 408­916­5750, www.reliantemc.com

 

Содержание U16/14-100k

Страница 1: ...Manual BV15 Analog transmitter U16 14 100k Distributed by Reliant EMC LLC 3311 Lewis Ave Signal Hill CA 90755 408 916 5750 www reliantemc com...

Страница 2: ...Distributed by Reliant EMC LLC 3311 Lewis Ave Signal Hill CA 90755 408 916 5750 www reliantemc com...

Страница 3: ...n 5 4 External filters 5 4 1 Differentiation input vs output filter 5 5 Maintenance 6 6 Trouble shooting 7 7 Accessories Options 9 8 Contact 9 Appendix Details and operation A1 Distributed by Reliant...

Страница 4: ...analog voltage signals Because of the optical transmission the system is very robust against EMS electromagnetic susceptibility It can withstand high electric and magnetic fields like they appear in...

Страница 5: ...o its input impedance do not use an extension Notice the differentiation of input and output filters see chapter4 1 4 1 Differentiation input vs output filter If you want to transmit analog voltages f...

Страница 6: ...rger to power the device inside the shielded room while EMI tests are running This might damage it Due to self discharge issues with NiMH batteries recharge batteries before use if the system has not...

Страница 7: ...at transmitter and receiver recharge batteries Test source signal directly at the device under test Device cannot be turned on cannot be charged Batteries damaged Internal fuse is broke Charger or ca...

Страница 8: ...r Comment Optical fiber LWL 1 xm x length in m simplex External batteries BP 60 25 6V 2 5Ah Connector cable for BP 60 SC 20 5m5m Length approx 20cm Charger with connector plugs CH1 5m Standard charger...

Страница 9: ...onnectors switches Fig a 1 shows the front sides of transmitter left and receiver right with connectors power push button with control LED Pwr On Off battery information LED Info charge plug Charge op...

Страница 10: ...el 2mm Hirschmann in the shown case Here the SD LED is integrated as well as the power switch At the rear side of the receiver the connectors for optical input and the power supply 6 8V 0 5A are place...

Страница 11: ...r into account while setting checking your measurement device Turn on all devices no order to be recognized Communication between transmitter and receiver will be indicated by the Signal detect LED at...

Страница 12: ...k messtechnik Others might lead to a damage of the system Only use battery packs and connector cables provided from mk messtechnik Other modules influence EMS performance and might damage the opto sys...

Отзывы: