SPECIFICATION

15

INFRARED ILLUMINATOR HOUSING

Model No 

                                        SLI070HB-2          SLI070HB-7

Power Input Voltage 

                               AC 24 V 

     AC 90-260 V

Radiant Distance 

                                           70 m(230ft)

Glass Thickness 

                                    6 mm tempered glass

IR LED     Wave Length                                            850 nm

 

    Quantity 

                                            96 Units

 

    Minimum illumination                             IR on 0 lux

Suitable camera dimension (HxDxW)         Less than 210x70x90 mm

Diameter of lens suggested 

                         Less than 45mm

IP Rating 

                                                             IP66

View angle of camera suggested 

                 Less than 50°

Material                                                      

Die-cast aluminum

Power consumption 

                                   35W 

          40W

Dimension 

                                        173 mm (W) x 450(D) x 154 mm (H)

Weight                                                                       Approx 3500 g

Operating temperature                                              -30 

o

C ~ 50 

o

C

Operating humidity  

                                          30% ~ 0% RH

Storage temperature                                              -40 

o

C ~ 60 

o

C

Camera Sync Input  

                                             Yes (V-sync)

NOTE:The specification is subject to change without notice.

70M (230ft)

0 lux with IR on

INFRARED ILLUMINATOR HOUSING 

Model Type

IP 67

   

        -30°C~50C° (-22°F~122°F)

   

        -40°C~60C° (-40°F~140°F)

< 210 x 70 x 90 mm (8.3" x 2.7" x 3.5")

   < 45 mm (1.8")

   

174 x 422 x 145 mm (6.9" x 16.6" x 5.7")

   Approx 3.75kg (8.3 lb)

Содержание SLI070HB

Страница 1: ...l Before attempting to connect or operate this product please read these instructions carefully and save this manual for future use CONTENTS SAFETY INFORMATION PART DESCRIPTION DIMENSION INSTALLATION...

Страница 2: ......

Страница 3: ...installation to ensure the quality and maintain safety 6 Power Please follow the labeled specifications on the unit and supply with the correct power If unsure of the actual power requirements please...

Страница 4: ...al certified parts of identical specifications Using unauthorized components can cause fire hazards and electric shock damage 13 Safety inspection After the unit maintenance has been completed the mai...

Страница 5: ...ion of the housing which may be used with most of ICR real Day and Night cameras 2 Dimension and Accessory Accessory Pack 1 Video sync cable 7 Spacer 2 Day night sync cable 8 2 Screws for tripod stand...

Страница 6: ...ble and video cable through the bracket then fix the bracket to the wall Loose the screws of the bracket for easy assembly if necessary Secondly take out the housing and open the side cover with hexag...

Страница 7: ...ass from the hole Attention Two solutions are available for waterproof 1 User can take out the spacer from the accessory pack and stick it right by the outlet Fig A or 2 use the three glands cover and...

Страница 8: ...board Camera position Inner Part Definition Fan 3 4 Open the side cover and you can see the housing inner part There are two installation types Power Adpator only in AC90 260V housing power connector...

Страница 9: ...1 1 Install the camera to the camera position as illustrated 3 4 1 2 Enable the day night sync funciton connect the day night sync cable to P203 and the to the BW GND port pin side BW brown line GND b...

Страница 10: ...INSTALLATION 3 4 1 3 Enable the video sync funciton connect the video sync cable to P202 and to the to the video output port of the camera IR LED driver board video sync cable...

Страница 11: ...INSTALLATION 3 4 1 4 Be sure to switch the S203 mode on the IR LED driver board to the Middle position Up Down Middle...

Страница 12: ...Other Brands 3 4 2 1 Install the camera to the camera position as illustrated 3 4 2 2 Enable the day night sync funciton connect the day night sync cable to P203 and the to the AL I GND port pin side...

Страница 13: ...INSTALLATION 11 3 4 2 3 Be sure to switch the S203 mode on the IR LED driver board to the Up position Up Down Middle...

Страница 14: ...ct the outside AC24V power supply to the section B L power N power Partial heater board Note For the AC90 260V housing type connect the power cable to the power port of the AC90 260V camera and to A s...

Страница 15: ...side cover and use the provided screws to fix the housing on the bracket with hexagon screw driver 13 Loosen the pan and tilt adjustment screw of the bracket to modify the angle of the housing and the...

Страница 16: ...INSTALLATION 14 Replace the side cover and tighten the screws A B 3 8 A B...

Страница 17: ...ng IP66 View angle of camera suggested Less than 50 Material Die cast aluminum Power consumption 35W 40W Dimension 173 mm W x 450 D x 154 mm H Weight Approx 3500 g Operating temperature 30 o C 50 o C...

Страница 18: ......

Отзывы: