Status display
In combination with 1-gang insert
In combination with 2-gang insert
In combination with a blind control insert
Operating the module: basic functions
Operation
Status feedback
Switching
All LED segments
light up when the
load is switched on
Dimming
The LED segments
light up corre-
sponding to the
brightness of the
load
Operation
Status feedback
Switching
• The LED seg-
ments to the right
of
A
show the
status of
channel 1
• The LED seg-
ments to the left
of
A
show the
status of
channel 2
Dimming
• The LED seg-
ments to the right
of
A
show the
dimming status
of channel 1
• The LED seg-
ments to the left
of
A
show the
dimming status
of channel 2
Operation
Status feedback
Raising/lowering
• A rotating LED
indicator shows
the direction of
movement of the
blind. Upwards in
a clockwise di-
rection.
• Display during
the running time
(max. 2 min)
Up/down in steps
• A rotating LED
indicator moves
according to the
blind direction.
Upwards in a
clockwise direc-
tion.
• Display: half turn
A
A
=
=
=
=
Setting the brightness of the status dis-
play
Switching orientation lighting on/off
All LED segments light up at min. brightness.
Standard: switched off
Switching memory function on/off
(Only in combination with dimmer inserts)
The device memorises the brightness level that was last
set.
Standard: switched off
1
Switching on memory function
2
Switching off memory function
Resetting to default settings
Operation
Status feedback
Upper LED segments
flash 4 times
Operation
Status feedback
Right LED segments
flash 4 times
Operation
Status feedback
All LED segments
flash 8 times
1
3
2
=
=
10 s
< 0,5 s
10x
10x
=
=
1
2
6x
6x
=
=
10 s
Changing operating mode
(Only available for modules with software from version
0B in combination with universal dimmer insert, 1-gang,
art. no. MEG5171-0000 from version 0B)
The insert automatically recognises the connected
loads. In some cases, the connected LED lamps may not
work correctly with the automatic load detection. In this
case you can switch the operating mode to RL LED (from
trailing edge phase to leading edge phase).
|
In the operating mode "leading edge phase for
LED lamps" (RL LED mode), LED lamps can only
be connected up to a lower dimmer load. (See
operating instructions "Universal dimmer insert".)
Standard: automatic load detection
1
Setting the RL LED mode
2
Resetting to automatic load detection
Gothaer Straße 29, 40880 Ratingen
www.merten.com
www.merten-austria.at
Customer care centre:
Operation
Status feedback
Lower LED segments
flash 4 times
Technical data
Display elements:
8 LED segments
Operating elements:
• 4 push-buttons
• Rotary knob/push-button
Connection:
module interface with 8 con-
tact pins