Status display 

In combination with 1-gang insert

In combination with 2-gang insert

In combination with a blind control insert

Operating the module: basic functions

Operation

Status feedback

Switching

All LED segments 

light up when the 

load is switched on

Dimming

The LED segments 

light up corre-

sponding to the 

brightness of the 

load

Operation

Status feedback

Switching

• The  LED  seg-

ments to the right 

of 

A

 show the 

status of 

channel 1

• The  LED  seg-

ments to the left 

of 

A

 show the 

status of 

channel 2

Dimming

• The  LED  seg-

ments to the right 

of 

A

 show the 

dimming status 

of channel 1

• The  LED  seg-

ments to the left 

of 

A

 show the 

dimming status 

of channel 2

Operation

Status feedback

Raising/lowering

• A  rotating  LED 

indicator shows 

the direction of 

movement of the 

blind. Upwards in 

a clockwise di-

rection.

• Display during 

the running time 

(max. 2 min)

Up/down in steps

• A  rotating  LED 

indicator moves 

according to the 

blind direction. 

Upwards in a 

clockwise direc-

tion.

• Display: half turn

A

A

=

=

=

=

Setting the brightness of the status dis-

play

Switching orientation lighting on/off

All LED segments light up at min. brightness.
Standard: switched off

Switching memory function on/off

(Only in combination with dimmer inserts)
The device memorises the brightness level that was last 

set.
Standard: switched off

1

Switching on memory function

2

Switching off memory function

Resetting to default settings

Operation

Status feedback

Upper LED segments 

flash 4 times

Operation

Status feedback

Right LED segments 

flash 4 times

Operation

Status feedback

All LED segments 

flash 8 times 

1

3

2

=

=

10 s

< 0,5 s

10x

10x

=

=

1

2

6x

6x

=

=

10 s

Changing operating mode

(Only available for modules with software from version 

0B in combination with universal dimmer insert, 1-gang, 

art. no. MEG5171-0000 from version 0B)
The insert automatically recognises the connected 

loads. In some cases, the connected LED lamps may not 

work correctly with the automatic load detection. In this 

case you can switch the operating mode to RL LED (from 

trailing edge phase to leading edge phase).

|

In the operating mode "leading edge phase for 

LED lamps" (RL LED mode), LED lamps can only 

be connected up to a lower dimmer load. (See 

operating instructions "Universal dimmer insert".)

Standard: automatic load detection

1

Setting the RL LED mode

2

Resetting to automatic load detection

Gothaer Straße 29, 40880 Ratingen
www.merten.com
www.merten-austria.at

Customer care centre:

Operation

Status feedback

Lower LED segments 

flash 4 times

Technical data

Display elements:

8 LED segments

Operating elements:

• 4 push-buttons
• Rotary knob/push-button

Connection:

module interface with 8 con-

tact pins

Dispose of the device separately from house-

hold waste at an official collection point. Pro-

fessional recycling protects people and the 

environment against potential negative ef-

fects.

Schneider Electric GmbH c/o Merten

Phone: +49 2102 - 404 6000

1

2

14x