Start Batch
Changes
to
Pause Batch
when batching is in progress. In the Paused
state, the button text is
Resume Batch
.
Clear Batch
Never
changes.
Start Fill
Changes
to
Stop Fill
in the Re-fill state.
Start Cleanou
t Changes
to
Stop Cleanout
in the Cleanout Weight and Cleanout
Time state.
None of the buttons are available under the following conditions:
•
When the Setpoint Method is Manual Speed.
•
When the Setpoint Method is Remote or Network, and R[078] is set to 1.
State indication text
Idle - Ready for Start
is the state indicator. It changes with the batching cycle. See
Setpoint Method Text
Local on screen
in the setpoint method indicator. It changes with the setpoint method.
See Setting the Setpoint on page 15.
Batch Statistics
Short-cut to the Batch Statistics Screen. See page 13.
Reset S-Total
Clears the Sub-Total. It may be cleared at any time. When cleared, a message
Subtotal
Cleared
appears on the screen.
Reset G-Total
Clears the Total. If you use a non-zero calibration password, you will be asked to enter it.
Enter the password to clear the total or push the ESC button in the password screen to
escape to the action screen without clearing the Master Total. When cleared, a message
G-Total Cleared
appears on the display.
Diag Menu
Takes you to the diagnostic system for troubleshooting your system. See Diagnosing
Problems on page 54.
Home Screen
Takes you back to the Main Screen from which you entered the
Action Menu
.
Calibrate Menu
Takes you to the Calibrate Menu. See Calibrating Your Controller on page 46.
Printer Menu
This menu allows you to edit or to print one of the four available print strings and the
Feeder Screen Display String. The print strings (1>, 2>, 3>, 4>) are lines of characters
that convey information to a printer for permanent record. The Feeder Screen Display
(D>) string allows you to place custom text on the main screen for easier controller
identification.