Attention:
to
carry
out
this
or
any
other
maintenance
operation
requiring
the
machine
casing
to
be
opened,
use
protective
gloves
to
avoid
being
cut
by
the
sharp
edges
of
the
sheet
steel Achtung:
für
diesen
Wartungseingriff
müssen,
wie
für
alle,
die
ein
Öffnen
des
Maschinengehäuses
erfordern,
C
8.3 HOW TO REPLACE THE UV LAMP
This operation should be performed by a qualified technician.ato
• Wear protection latex disposable gloves to avoid touching the lamp with your
hands. The contact with the skin can prejudice the duration of the lamp
How to replace the lamp:
• Remove the external casing (fig. 23) by removing the rear screws.
• Unscrew the two screw fasteners on the box (fig. 24)
• Remove the UV box from its support (fig. 25)
• Unscrew the tightening screw and remove the cover
C
(fig.26)
• remove the lamp and replace it with one of the same kind (fig.27)
• mount again all the components in reverse
Attention! direct irradiation of the UV lamp is dangerous both
for the eyes and for the skin
The lamp must be replaced every 6000 hours of working
(about 8 months)
GB
9
FAULTS AND REMEDIES
GB
Warning! The operations should be carried out by a qualified professional.
9.1 DIAGNOSIS AND OPERATING ANOMALIES
This section includes the typical anomalies that could occur.
Many of these problems are not caused by the cooler, but they could be brought about by the electricity supply or by an incorrect use of the water cooler.
In the
ANOMALY
column, the problems reported by the customer are listed.
In the
POSSIBLE CAUSES
column, the “probable reasons” behind the problem are listed.
In the
INTERVENTION
column, the corresponding corrective action is listed.
16