WIRING OF DANFOSS ELECTRONIC MODULE
12/24V
12/24V + 110V
FOLLOW THE WIRING DIAGRAM ABOVE AND DESCRIPTION BELOW TO MATCH WIRES.
THE 12/24 + 110V MODELS WILL HAVE AN ADDITIONAL POSITIVE (L) AND NEUTRAL (N)
SYMBOL FOR THE TWO 110V LEADS.
MM1 AND MM2 12/24V MODELS:
(-) NEGATIVE LEAD =
BLACK
WIRE (NEGATIVE 12/24V)
(+)POSITIVE LEAD =
RED
WIRE (INCOMING 12/24V POWER)
(+)POSITIVE LEAD =
THIN
RED
WIRE (FAN)
(F) NEGATIVE LEAD =
THIN
BLACK
WIRE (FAN)
(D) FAULT LIGHT =
BROWN
WIRE
(C) THERMOSTAT =
GREEN
WIRE
(P) OPEN TERMINAL =
NO WIRE
(T) THERMOSTAT =
PURPLE
WIRE
MM1 AND MM2 12/24V + 110V WITH AUTO CHANGE-OVER MODELS:
(L) 110V LIVE WIRE =
BLACK
WIRE
(N) 110V NEUTRAL WIRE =
WHITE
WIRE
(-) NEGATIVE LEAD =
BLACK
WIRE (NEGATIVE 12/24V)
(+) POSITIVE LEAD =
THIN
RED + 12V RED
WIRE (FAN + INCOMING 12/24V POWER)
(F) NEGATIVE LEAD =
THIN
BLACK
WIRE (FAN)
(A) INTERIOR LIGHT =
NO WIRE
(C) INTERIOR LIGHT =
NO WIRE
(D) FAULT LIGHT =
BROWN
WIRE
(C) THERMOSTAT =
GREEN
WIRE
(P) OPEN TERMINAL =
NO WIRE
(T) THERMOSTAT =
PURPLE
WIRE
Содержание KOOL-TEMP