MERLYN MB12 Скачать руководство пользователя страница 3

FIG 4

  

4. Plumb the wall profiles SP0L909C using the vertical
element of the spirit level. Mark 3 holes, drill with 6mm 
masonry bit and fit wall plugs SP0B08070. Using the 3 
Screw A2403001, fix wall profiles to wall. 

Fig 4. 

NOTE: Only silicone the wall profile after fixing to the wall
 (see sealing section). Do not silicone on the back of the 
wall profile before fixing to the wall.

3. Position the wall profile SP0L909C so the
 seal on the moving panel sits on the inside 
edge of the bath. 

Fig 3.

FIG 3

INSIDE

1. The screen is reversible for fitting to a wall on the right or left. The screen is set up for Left hand use. If you need to reverse it, unscrew one of the
 brackets and remove the moving panel A 

Fig 1. 

FIG 1

FIG 2

NOTE: Ensure the upright seal is on the inside.

 Fig 2.

2. Turn the hinge post upside down, reinsert the moving panel (do not turn panel upside down). Reattach the bracket.  

Fig 1. 

The screen can then 

be fitted on the Right hand Side of the Bath. Ensure the upright seal  is on the inside. 

Fig 2.