55 CM WIDE BUILT-IN FRIDGE-FREEZERS
Technical Manual
I
04-10-22/01
15-33
Language
Issue/Edition
Page
8. Thermo fuse (No-Frost only)
INFORMATION:
How It Works
: it is a safety device which is tripped, cutting off the electrical power
supply to the 72 W and 15 W resistors, when the temperature of the freezer evaporator
reaches approxi85 °C.
The thermo fuse is housed on the metal support in contact with the freezer evaporator.
This component, having been tripped due to excessive temperature, can no longer be
used.
POSSIBLE CAUSE OF MALFUNCTION:
Connection on thermo fuse
Wiring
Thermo fuse
TESTING:
General on the appliance
: carry out the check using the Autotest procedure and
check for correct functioning of the defrosting resistors (a malfunction could in any
case be due not only to the thermo fuse: see paragraphs relating to the two loads).
Wiring and component
: check for continuity and short circuits; check the connec-
tions (connectors and terminals).