background image

TO SET OUTPUT DURATION

The receiver can be set for either constant or momentary closure on the

output contacts for each channel (A and B). (Use constant closure only if

constant pressure is needed.) With the jumper in “1” (Momentary) position,

the contacts will close for 150ms regardless of the length of radio

transmission. With the jumper in “2” (Constant) position, the contacts will

stay closed as long as the radio continues transmitting.

CM8002ANZ-1 433MHz 2 Channel Billion and
Rolling Code Channel Receiver

Constant signal
(Hold to run)

Momentary

A

nt

OUT A OUT B

Input

AC / DC

LearnA LearnB

Test

Test

A

B

LDS2

LDS1

LDS3

LDS4

Jumper

Channel A

Program buttons

(Channel A & B )

Command buttons

(Channel A & B)

Indicator lights

(Channel A & B)

Jumper

Channel B

Antenna Connection

>24V < 24V

Transformer

or

Power Source

CN2

CN1

Indicator lights

(momentary or constant)

< 24V

12-16V AC, @ 30mA

12-24V DC, @ 30mA

> 24V

16-30V AC, @ 30mA

24-30V DC, @ 30mA

MERLIN

MERLIN

Example of

use Gate

Controler

Example of Use

Garage door motor

Chamberlain Australia Pty Ltd

PO Box 1446

Lane Cove NSW 1595

Chamberlain New Zealand Ltd

PO Box 100 221

North Shore 0745

gomerlin.com.au

gomerlin.co.nz

CM842

CM128

C940

C943

C945

CM844

4330A

4333A

4335A

Compatible Remotes:

Merlin Professional

Compatible Remotes:

Chamberlain

Open Garage door

Channel A

Open Garage and Gate

Channel A and B

Open Gate

Channel B

Example of Use