TO SET OUTPUT DURATION
The receiver can be set for either constant or momentary closure on the
output contacts for each channel (A and B). (Use constant closure only if
constant pressure is needed.) With the jumper in “1” (Momentary) position,
the contacts will close for 150ms regardless of the length of radio
transmission. With the jumper in “2” (Constant) position, the contacts will
stay closed as long as the radio continues transmitting.
CM8002ANZ-1 433MHz 2 Channel Billion and
Rolling Code Channel Receiver
Constant signal
(Hold to run)
Momentary
A
nt
OUT A OUT B
Input
AC / DC
LearnA LearnB
Test
Test
A
B
LDS2
LDS1
LDS3
LDS4
Jumper
Channel A
Program buttons
(Channel A & B )
Command buttons
(Channel A & B)
Indicator lights
(Channel A & B)
Jumper
Channel B
Antenna Connection
>24V < 24V
Transformer
or
Power Source
CN2
CN1
Indicator lights
(momentary or constant)
< 24V
12-16V AC, @ 30mA
12-24V DC, @ 30mA
> 24V
16-30V AC, @ 30mA
24-30V DC, @ 30mA
MERLIN
MERLIN
Example of
use Gate
Controler
Example of Use
Garage door motor
Chamberlain Australia Pty Ltd
PO Box 1446
Lane Cove NSW 1595
Chamberlain New Zealand Ltd
PO Box 100 221
North Shore 0745
gomerlin.com.au
gomerlin.co.nz
CM842
CM128
C940
C943
C945
CM844
4330A
4333A
4335A
Compatible Remotes:
Merlin Professional
Compatible Remotes:
Chamberlain
Open Garage door
Channel A
Open Garage and Gate
Channel A and B
Open Gate
Channel B
Example of Use