4. Press the desired channel button to program

another channel. Repeat programming procedures
in steps 2 and 3 above.

5. When finished programming each desired channel,

momentarily press the 

PRINCE CASTLE

 logo to

end the Program Mode.  This saves the program
changes you have made for all channels.
See figure 5.

      

Figure  5

  6. You can change the sound level of the alarm in

RUN MODE

.  Press and hold the 

PRINCE CASTLE

logo; then, within six seconds, press either the

SCAN UP

 Arrow button or the 

SCAN DOWN

 Arrow

button.  The 

SCAN UP

 Arrow button adjusts the

sound level to the louder alarm, the 

SCAN DOWN

Arrow button adjusts the sound level to the lower
alarm.

OPERATION

1. Press a channel button to activate a timing cycle.

(All channels can be activated and running at the
same time.)  The time remaining will countdown in
the 

TIME

 display, and the time value 

M:S

 or 

H:M

 will

be illuminated.  See figure 6

     

Figure 6

2. Press the desired channel button three times within

five seconds to cancel an active timing cycle.

IMPORTANT:

 The channel timer button’s multicolored

LED indicator shows the status of the timer.  The
indicator has three colors:  green, yellow, and red.  The
LED will be green during the first 70% of the count-
down.  It changes to yellow during the next 20% of the
countdown.  It will be red during the final 10% of the
countdown, and will start flashing red once the time
has run out.

3. The timer will countdown from the programmed

value to zero.  At zero, the display flashes 

End

 and

the alarm sounds.  See figure 7.

Figure 7

4. When the timing cycle is complete, and the alarm

sounds, press the channel button to cancel the
alarm.  See figure 7.

 

59:59

P r o g

P r o g

P r o g

P r o g

P r o g

 1:00

P r o g

P r o g

P r o g

P r o g

P r o g

- - - -

- - - -

- - - -

- - - -

- - - -

- - - -

 3:00

- - - -

- - - -

- - - -

- - - -

- - - -

 End

- - - -

- - - -

- - - -

- - - -

- - - -

740-521revA

Printed in USA 3/06 © 2006 

Содержание 740-Horizontal Series

Страница 1: ...placed or repaired at the option of Prince Castle Inc without cost to the customer for parts and labor This equipment is portable charges for on location service e g trip charges mileage are not included in the provisions of this warranty This warranty is subject to the following exceptions conditions Use of any non genuine Prince Castle parts voids this warranty All labor to be performed during r...

Страница 2: ...each channel In the Run Mode it is used in conjunction with logo button to increase the volume In the program mode it decreases time values for each channel In the run mode it is used in conjunction with logo button to decrease the volume Activates Program Mode and used to adjust the alarm sound level PROGRAMMING 1 Press and hold the PRINCE CASTLE logo for six seconds The TIME displays change will...

Страница 3: ... the same time The time remaining will countdown in the TIME display and the time value M S or H M will be illuminated See figure 6 Figure 6 2 Press the desired channel button three times within five seconds to cancel an active timing cycle IMPORTANT The channel timer button s multicolored LED indicator shows the status of the timer The indicator has three colors green yellow and red The LED will ...

Страница 4: ...ear Cover T44H T66H 3 740 072S Main P C Board T44H 740 070S Main P C Board T66H 740 244S Main P C Board T88H 4 740 079S Wing Board T88H Only 5 88 653 2 4S Speaker Assy 6 541 135 Speaker Shim 7 740 056S Switch Panel Assy T88H 740 055S Switch Panel Assy T66H 740 054S Switch Panel Assy T44H 8 740 058 Front Cover T88H 740 057 Front Cover T66H T44H 9 70 048S Knob W Hardware 10 72 292S Power Supply 110 ...

Страница 5: ...it until channels are in stop mode Display does mode not show Prog Logo Switch inoperable Replace Switch Panel D Unit enters program mode The channel is still counting Wait until channel is in stop mode Display shows Prog but Arrow Switch inoperable Replace Switch Panel cannot change times Circuit inoperable Replace Main Circuit Board E Unable to start stop or store Circuit inoperable Replace Swit...

Страница 6: ...WIRING DIAGRAM 740 T44H T66H T88H 6 Printed in USA 3 06 2006 740 521revA ...

Отзывы: