WARNING! TO PREVENT SERIOUS INJURY:
Make sure air supply is off and release all residual
air in system before installing Regulator.
1. Thread gauge onto front of Regulator body.
2. Securely mount Regulator in vertical position
as close as possible to the tool connection.
Note:
Air flow must be in the same
direction as arrow on Regulator body.
3. System piping should be 1/2″ minimum.
Avoid using unnecessary fittings and
couplings that restrict the flow of air.
4. Turn Bowl fully clockwise. Make sure
it is properly installed before use.
5. Connect air supply to Inlet Port.
Connect air tool to Outlet Port.
Inlet
Outlet
Operating Instructions
1. Pull Adjustment Knob upwards to
unlock. Turn Knob counter‑clockwise
until it stops (closed position).
2. Turn Adjustment Knob clockwise until the
desired outlet pressure is reached.
3. Push down on Adjustment Knob to lock.
Maintenance
BEFORE EACH USE,
inspect the general
condition of the tool. Check for:
• loose fittings
• cracked or deformed o‑rings
• damaged pressure gauge or hose
• any other condition that may
affect its safe operation.
1. Twist Bowl counter‑clockwise and pull
down to remove from Body. Clean
or replace filter as needed.
2. Reinstall Filter and Bowl. Twist Bowl
clockwise to lock into place.
Record Serial Number Here:
Note:
If product has no serial number, record month and year of purchase instead.
Note:
Reference UPC 193175433923.
Specifications
Flow
140 CFM Max. at 100 PSI
Gauge Range
5 PSI ‑ 150 PSI
Max. Pressure
250 PSI
Filtration
40 Microns
Inlet and Outlet Size
1/2″ NPT