Item 58177                              

For technical questions, please call 1-888-866-5797.                                       

 

22g

SAVE THESE INSTRUCTIONS

Installation

WARNING!  TO PREVENT SERIOUS INJURY:

 

Turn off air supply and release residual 

pressure before installing Regulator.

1.  Thread gauge onto front of Regulator body.

2.  Securely mount Regulator in vertical position 

as close as possible to the tool connection.

3.  System piping should be 3/8″ minimum. 

Avoid using unnecessary fittings and 

couplings that restrict the flow of air.

4.  Connect air supply to Inlet Port. 

Connect air tool to Outlet Port.

Inlet

Outlet

Operating Instructions

1.  Pull Adjustment Knob outward to 

unlock. Turn Knob counter‑clockwise 

until it stops (closed position).

2.  Turn Adjustment Knob clockwise until the 

desired outlet pressure is reached.

3.  Push Adjustment Knob inward to lock.

Maintenance

BEFORE EACH USE,

 inspect the general 

condition of the tool.  Check for:

•  loose fittings
•  cracked or deformed o‑rings
•  damaged pressure gauge or hose
•  any other condition that may 

affect its safe operation.

Record Serial Number Here: 

 

Note:

 If product has no serial number, record month and year of purchase instead.

Note:

 Reference UPC 193175433879.

Specifications

Flow

208 CFM Max. at 100 PSI

Gauge Range

5 PSI ‑ 150 PSI

Max. Pressure

300 PSI

Inlet and Outlet Size

3/8″ NPT