Mercury MTTR01 Скачать руководство пользователя страница 12

 

MTTR01 User Manual 

Frequency 

RANGE 

RESOLUTION 

ACCURACY 

Remark 

9.999Hz 

0.001Hz 

± (1.0% of rdg + 5) 

Auto range 

99.99Hz 

0.01Hz 

999.9Hz 

0.1Hz 

9.999kHz 

1Hz 

99.99kHz 

10Hz 

999.9kHz 

100Hz 

9.999MHz 

1kHz 

Not Specified 

Input Voltage: 0.5 ~3Vpp 

Overload protection: 600Vrms 

 

OPERATING INSTRUCTIONS 
 

VOLTAGE MEASUREMENT 

 

1.

 

Connect red test lead to “-II-°C°F VΩHzhFE” jack, black lead to “COM” 
jack. 

2.

 

Set RANGE switch to desired VOLTAGE option (AC, DC or combine).  

3.

 

Connect test leads to device or circuit being measured. 

4.

 

Turn on power of the device or circuit being measured. The voltage 
value will appear on the digital display along with the voltage polarity. 

 

Please note: 

 

In small range, the meter may display an unstable reading when the 
test leads have not been connected to the load to be measured. It is 

normal and will not affect the measurements. 

 

To avoid damage to the meter, don’t measure a voltage which exceeds 

600Vrms.  

 

CURRENT MEASUREMENT 

1.

 

Set the range switch to desired measuring range (uA, mA or A), if value 

of the measure is unknown, always ensure to start with highest value 
until appropriate reading figure is displayed. 

Содержание MTTR01

Страница 1: ...Item ref 600 104UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE User Manual...

Страница 2: ...The rotary switch should be in the right position and no changeover of range shall be made while measurement is conducted to prevent damage When the tester is working at an effective voltage over 60V...

Страница 3: ...ake out the battery when not using for a long time Check the battery regularly replace the battery immediately if any signs of leaking appear Battery acid will damage the tester General Specifications...

Страница 4: ...MTTR01 User Manual Layout...

Страница 5: ...tch for selecting different measuring ranges and also serves as an ON OFF switch To preserve battery life please ensure the range switch is turn to OFF position when not in use 7 10A Probe socket sock...

Страница 6: ...ched off 13 Strong magnet that allows meter to be attached to any iron steel surface in case both hands are required to take the measurement 14 Mini USB socket at the bottom of the unit to connect to...

Страница 7: ...is selected use Select button to choose between resistance measuring diode testing and continuity testing 7 Relative mode is selected use Rel USB button to select between auto range mode and relative...

Страница 8: ...e current or resistance The length of the bar is proportionate to the 0 5999 digital count above it The bar graph has a sampling rate 10 times higher of the digital number display this make it ideal f...

Страница 9: ...nd 600V Frequency Range 40Hz 400Hz Overload Protection 600Vrms Reading True rms Max Input voltage 750Vac rms DC Current RANGE RESOLUTION ACCURACY Remark 600uA 0 1uA 1 0 of rdg 7D Auto range 6000uA 1uA...

Страница 10: ...10 sec and use no more than once every 15 min Frequency Range 40Hz 400Hz Reading True rms Resistance RANGE RESOLUTION ACCURACY Remark 600 0 1 1 0 of rdg 5D Auto range 6K 1 0 8 of rdg 5D 60k 10 600k 1...

Страница 11: ...ad protect 600Vdc ac rms Transistor Range Resolution Test condition hFE 1 Vce 2 2V Ib 4uA Over load protect 600Vdc ac rms Temperature RANGE Scope RESOLUTION ACCURACY C 20 to 0 C 0 1 C 6 0 of rdg 5 C 0...

Страница 12: ...to device or circuit being measured 4 Turn on power of the device or circuit being measured The voltage value will appear on the digital display along with the voltage polarity Please note In small r...

Страница 13: ...ddition 10A function is designed for intermittent use only RESISTANCE MEASUREMENT 1 Connect red lead to II C F V HzhFE and black lead to COM 2 Set the range switch to three functions are available by...

Страница 14: ...t until is displayed on the screen 3 Connect the red test lead to the anode of the diode to be measured and black test lead to cathode 4 The meter will show the approximate forward voltage of the diod...

Страница 15: ...the approximate hFE value TEMPERATURE MEASUREMENT 1 Using the K type thermocouple connect red lead to II C F V HzhFE and black lead to COM 2 Set the Range switch to C F 3 Attach the end of the thermo...

Страница 16: ...e and enter relative mode with displayed on the screen and reading display with 0 2 Now any measurement taking the unit will only display the difference between the reference value and the current rea...

Страница 17: ...MTTR01 User Manual Software http cdn avslgroup com downloads 600104_MTTR01 software zip...

Страница 18: ...MTTR01 User Manual Setting BATTERY AND FUSE REPLACEMENT...

Страница 19: ...ery into the case top Tidy the battery leads so that they will not be pinched by the battery cover 4 The meter is protected by fuses mA F0 5A 600V Fast blow Breaking capacity is 20KA dimensions are 38...

Страница 20: ...ssed as Electrical or Electronic equipment and should not be disposed with other household or commercial waste at the end of its useful life The goods must be disposed of according to your local counc...