COD100B 

Carbon Monoxide Alarm 

Item ref: 350.135UK 

User Manual 

 

 

 

 

 

Содержание COD100B

Страница 1: ...COD100B Carbon Monoxide Alarm Item ref 350 135UK User Manual...

Страница 2: ...ntilation is lacking Please read through the following manual carefully on how to correctly install operate and maintain the device and also for action to be taken in the event of detection of dangero...

Страница 3: ...level It is advised to locate the alarm near the potential source of CO such as rooms with a boiler fireplace or gas oven For optimum detection the alarm needs to be installed at least 1 5m above the...

Страница 4: ...roundings When the alarm is powered the green power LED will flash once every 45 seconds to indicate it is working When the working voltage drops below 3 5V the alarm will beep when the power LED flas...

Страница 5: ...d be below 25ppm Therefore when the count is below 25 the LCD will only display 0ppm and the temperature reading in a 30 second cycle To meet EN50291 standards the alarm will activate within following...

Страница 6: ...o all active gas including chemical cleaners Always perform a manual test after cleaning to ensure the alarm is working normally Also the battery compartment needs to be checked on regular basis for s...

Страница 7: ...an open door or window for fresh air Do a head count to check all persons are accounted for 3 DO NOT re enter the premises or move away from the door window until the alarm has stopped 4 Call the UK E...

Страница 8: ...led appliances in enclosed spaces Do not use fueled generators in enclosed space Paraffin flueless heaters should not be used in a bedroom or an enclosed space Ensure all flues chimneys or other venti...