                                                                                                            350.129UK User Manual

 

Testing and usage: 

 

1.

 

Turn the smoke detector anti-clockwise to remove it from the installation panel. 

2.

 

Slide the red battery pin on the back of the unit to the right and locate in the groove at position On. 

3.

 

Align the 2 locating slots in the smoke detector with the 2 tags on the installation panel and rotate it 
clockwise until it locks into position. 

4.

 

Depress and hold the test/hush button to check the alarm and red warning LED are functioning 
correctly. After testing the LED will flash every 10 seconds to inform you the unit is in low sensitivity 

(hush) mode. After around 10 mins the LED will flash every 40 seconds which indicates the unit is 
now in standard operating mode. To enter the low sensitivity mode at any time press and hold the 

button until the alarm is sounded and the LED flashes every 10 seconds. 

5.

 

If the alarm sounds due to detecting smoke at any time, an alarm memory will be saved. This will be 
evident as the green LED will flash 3 times repeatedly and will last for 24 hours until clearing itself. 

 

Please note: 

 

Test the alarm weekly. 

 

No user serviceable parts inside. 

 

When the battery power is low the red LED will flash and an intermittent beep will sound to indicate 

the unit needs replacing. 

 

Do not use in dusty and smoky environments. 

 

Keep out of the reach of children. 

 

Please retain this manual for future reference. 

 

 

 

 

         

 

 

   

Intended for Fire Safety and installed in buildings 

     

 

 

Essential characteristic 1: Pass 

 

 

 

              19   

 

Essential characteristic 2: Pass 

            2831 

 

Essential characteristic 3: Pass 

   2831-CPR-F0913 

 

Essential characteristic 4: Pass 

 

                EN14604:2005/AC:2008   

Essential characteristic 5: Pass 

 

            Photoelectric Smoke Detector 

Essential characteristic 6: Pass 

 

 

    350.129UK-001 

 

Essential characteristic 7: Pass 

 

 

 

 

 

Essential characteristic 8: Pass 

 

This product is classed as Electrical or Electronic equipment and should not be disposed with other household or commercial waste  

at the end of its useful life. The goods must be disposed of according to your local council guidelines

 

Errors and omissions excepted.

  