background image

 

Mercury Security © 2019 

MR62e 

DOC 10107-0057 

REV 1.02 

Page 8 

 

Mounting Plate Dimensions: 

 

Warranty 

Mercury Security warrants the product is free from defects in material and workmanship under normal use 
and  service  with  proper  maintenance  for  one  year  from  the  date  of  factory  shipment.    Mercury  Security 
assumes  no  responsibility  for  products  damaged  by  improper  handling  or  installation.    This  warranty  is 
limited to the repair or replacement of the defective unit. 

There  are  no  expressed  warranties  other  than  set  forth  herein.    Mercury  Security  does  not  make,  nor 
intends,  nor  does  it  authorize  any  agent  or  representative  to  make  any  other  warranties,  or  implied 
warranties, and expressly excludes and disclaims all implied warranties of merchantability or fitness for a 
particular purpose. 

All returns must be accompanied by a Return Material Authorization (RMA) number obtained from customer 
service, and prepaid postage and insurance. 

Liability

 

The  Interface  should  only  be  used  to  control  exits  from  areas  where  an  alternative  method  for  exit  is 
available.    This  product  is  not  intended  for,  nor  is  rated  for  operation  in  life-critical  control  applications.  
Mercury Security is not liable under any circumstances for loss or damage caused by or partially caused 
by the misapplication or malfunction of the product.  Mercu

ry Security’s liability does not extend beyond the 

purchase price of the product. 

 

3.85 [97.8]

2.35 [59.7]

5.50 [139.7]

3.63 [92.1]

3.30 [83.8]

3.63 [92.1]

Ø0.16 [Ø4.0]

MR50 MGT HOLES

4PL

Ø0.16 [Ø4.0]

3-GANG MGT HOLES

4PL

Содержание MR62e

Страница 1: ...on Six inputs are provided that may be used for monitoring the door contacts exit push buttons and alarm contacts Input circuits can be configured as unsupervised or supervised The MR62e requires PoE...

Страница 2: ...osed Contact TB6 1 NO Relay K3 Normally Open Contact TB6 2 3 C Relay K3 Common Contact TB6 3 NC Relay K3 Normally Closed Contact TB6 4 NO Relay K4 Normally Open Contact TB6 5 4 C Relay K4 Common Conta...

Страница 3: ...ve power during steps 4 6 1 Set S1 DIP switches to 1 2 ON 3 4 OFF 2 Apply power to the MR62e 3 Watch for LEDs 1 2 and 3 4 to alternately flash at a 0 5 second rate 4 Within 10 seconds from applying po...

Страница 4: ...rt not only open and closed but also open circuit shorted grounded and foreign voltage A supervised input circuit requires two resistors be added to the circuit to facilitate proper reporting The stan...

Страница 5: ...to be downloaded 1 sec ON 1 sec OFF 2 Input IN1 Status OFF Inactive ON Active Flashing Fault See note 2 3 Input IN2 Status OFF Inactive ON Active Flashing Fault See note 2 4 Input IN3 Status OFF Inac...

Страница 6: ...30 Vdc Inputs Six unsupervised supervised End of Line resistors 1k 1k ohm 1 watt standard Reader Interface Power 12 Vdc 5 A maximum RVO TB7 4 Communication 2 Wire RS 485 OSDP protocol four devices max...

Страница 7: ...structive Attack I 14 Additional Mounting Information Sources for the optional items shown below 3 gang stainless steel blank cover Available from Leviton part number 84033 40 Graybar part number 8815...

Страница 8: ...d warranties and expressly excludes and disclaims all implied warranties of merchantability or fitness for a particular purpose All returns must be accompanied by a Return Material Authorization RMA n...

Отзывы: