1.  General:  

The MR62e OSDP reader interface provides a network connected interface to control two physical barriers 
using OSDP readers and provides a solution for the OEM integrator for interfacing to OSDP readers and 
door hardware.  The  on-board Ethernet  with PoE/PoE+ support  enables easy installation.  The MR61e 
supports up to four OSDP readers configured as paired or alternate readers. 

 

Note:  For UL, the Power Sourcing Equipment (PSE) such as a PoE/PoE+ enabled network switch and/or 
PoE/PoE+ power injectors must be UL Listed under UL294B. 

One  serial  2-wire  RS-485  communication  port  is  available  that  can  accommodate  up  to  four  OSDP 
readers.  Four Form-C relay  outputs may be used for door strike control  or alarm signaling.  The relay 
contacts are rated at 2 A @ 30 Vdc, resistive and are in a dry contact configuration.  Six inputs are provided 
that may be used for monitoring the door contacts, exit push buttons, and alarm contacts.  Input circuits 
can be configured as unsupervised or supervised.   The MR62e requires PoE, PoE+ or local 12 Vdc for 
power.  The MR62e may be mounted in a 3-gang switch box; a mounting plate is supplied with the unit or 
be  mounted  in  an  enclosure;  the  supplied  mounting  plate  has  mounting  holes  that  match  the  MR50 
mounting footprint. 

2.  MR62e Hardware: 

 

MR62e Layout 

TB

5

1

IN1

IN2

IN3

IN4

IN5

IN6

VO

GN
D

V

IN

GN
D

V

IN

POE

J5

NO

NC

2

-C

NO

NC

1

-C

NO

NC

4

-C

NO

NC

3

-C

K1

K2

K3

K4

K4

K3

K2

K1

RVO

GND TR- TR+

J3

J4

J1

1

05
19
-0

00
0-

F, RE
V-A

7

6

5

4

3

2

1

2

3

4

1

S1

ON

|

|V

INPUTS

RELAYS

J5: INPUT
     POWER
     SELECT

12 Vdc IN &

AUX POWER
OUTPUT

2

.55 

[6

4

.7

7

]

2

.55 

[6

4

.7

7

]

5

.4 [

1

3

7

.1

6

]

STATUS

LEDs

2.35 [59.69]

2.75 [69.85]

.2 [5.08]

S1: DIP

SWITCH

J3: TAMPER

SWITCH

TO OSDP

READERS

LINK

(GREEN)

SPEED

(YELLOW)

J4: TIA-485

TERMINATION

JUMPER

Ø.125 [3.18]
6 PLACES

EARTH

GROUND

J1: ETHERNET RJ45
      CONNECTOR

This device complies with part 15 of the FCC Rules.  Operation 
is subject to the following two conditions: (1) This device may 
not  cause  harmful  interference,  and  (2)  this  device  must 
accept any interference received, including interference that 
may cause undesired operation. 

Содержание MR62e

Страница 1: ...on Six inputs are provided that may be used for monitoring the door contacts exit push buttons and alarm contacts Input circuits can be configured as unsupervised or supervised The MR62e requires PoE...

Страница 2: ...osed Contact TB6 1 NO Relay K3 Normally Open Contact TB6 2 3 C Relay K3 Common Contact TB6 3 NC Relay K3 Normally Closed Contact TB6 4 NO Relay K4 Normally Open Contact TB6 5 4 C Relay K4 Common Conta...

Страница 3: ...ve power during steps 4 6 1 Set S1 DIP switches to 1 2 ON 3 4 OFF 2 Apply power to the MR62e 3 Watch for LEDs 1 2 and 3 4 to alternately flash at a 0 5 second rate 4 Within 10 seconds from applying po...

Страница 4: ...rt not only open and closed but also open circuit shorted grounded and foreign voltage A supervised input circuit requires two resistors be added to the circuit to facilitate proper reporting The stan...

Страница 5: ...to be downloaded 1 sec ON 1 sec OFF 2 Input IN1 Status OFF Inactive ON Active Flashing Fault See note 2 3 Input IN2 Status OFF Inactive ON Active Flashing Fault See note 2 4 Input IN3 Status OFF Inac...

Страница 6: ...30 Vdc Inputs Six unsupervised supervised End of Line resistors 1k 1k ohm 1 watt standard Reader Interface Power 12 Vdc 5 A maximum RVO TB7 4 Communication 2 Wire RS 485 OSDP protocol four devices max...

Страница 7: ...structive Attack I 14 Additional Mounting Information Sources for the optional items shown below 3 gang stainless steel blank cover Available from Leviton part number 84033 40 Graybar part number 8815...

Страница 8: ...d warranties and expressly excludes and disclaims all implied warranties of merchantability or fitness for a particular purpose All returns must be accompanied by a Return Material Authorization RMA n...