Mercury Security MR52 Скачать руководство пользователя страница 1

 

Mercury Security Corporation © 2011 

MR52 

DOC  10107-0015 

REV 2.02 

 Page   1 

www.mercury-security.com 

2355 MIRA MAR AVE. LONG BEACH, CA 90815-1755, (562)986-9105 FAX (562) 986-9205 

This  device  complies  with  part  15  of  the  FCC  Rules.  
Operation is subject to the following two conditions: (1) This 
device  may  not  cause  harmful  interference,  and  (2)  this 
device  must  accept  any  interference  received,  including 
interference that may cause undesired operation. 

MR52 READER INTERFACE 

Installation and Specifications: 

1.  General: 

The  MR52  reader  interface  provides  a  solution  to  the  OEM  system  integrator  for  interfacing  to 
TTL/Wiegand/RS-485  type  readers  and  door  hardware.    The  MR52  can  accept  data  from  reader  with 
clock/data, Wiegand or RS-485 signaling, provide a tri-stated LED control and buzzer control.  Six form-C 
relay outputs may be used for strike control or alarm signaling.  Eight supervised inputs are provided for 
monitoring  the  door  contact,  exit  push  button  and  alarm  contacts.    Communication  to  the  MR52  is 
accomplished via a 2-wire RS-485 interface.   

The MR52 requires 12 to 24Vdc for power.  See the following figure for component location. 

 

 

IN

1

IN

2

IN

3

IN

4

TB1

TB2

INP
U

TS

TB3

IN

5

IN

6

TB4

IN

7

IN

8

TB5

TMP

GND

PFL

GND

A

B

1

2

3

4

5

6

7

8

PFL R1 R2

TMP

J7

J8

J9

J1

0

J14

J13

U1

S1

1
2
3

4
5
6
7
8

R

EA

DE

2

VO

LE

D

BZR

CL

K

D

AT

G

ND

D1

D0

VO

LE

D

BZR

CL

K

G

ND

D1

D0

D

AT

R

EA

DE

1

TB8

TB9

NC

NO

C

NC

R

LY

 1

C

NO

R

LY

 2

R

LY

 4

R

LY

 3

NO

C

NO

NC

C

NC

R

LY

 6

R

LY

 5

NO

C

NO

NC

C

NC

TB10

TB11

TB12

J12

K1

K2

K3

K4

K5

K6

12V PT

J2

J3

J15

2 W  4W

RS-485

TR-

R+

R-

GND

TR+

TB6

J5

J6

TB7

VIN

GND

J11

J5, J6

TERMINATOR

K1

K2

K3

K4

K5

K6

2.0

[50.

80

]

3.0

[76.

20

]

2.0

[50.

80

]

8.0

[203.

20

]

.25 [6.35]

5.50 [139.70]

6.00 [152.40]

STATUS LEDs

READER INTERFACE

DIP SWITCHES

RELAY STATUS LEDs

OUTPUTS

Ø.156 [Ø4.0]

8 PLACES

SIO COMMUNICATION

PORT, RS-485

POWER IN

12-24Vdc

INPUTS

.50 [12.70]

Содержание MR52

Страница 1: ...ay be used for strike control or alarm signaling Eight supervised inputs are provided for monitoring the door contact exit push button and alarm contacts Communication to the MR52 is accomplished via...

Страница 2: ...RS 485 interface Power to the reader is selectable 12Vdc or input voltage passed through PT 125mA maximum per reader port This selection is made via jumper J2 and is made for both reader ports For th...

Страница 3: ...t be used The following two circuits are recommended Locate the protection circuit as close to the load as possible within 12 inches 30cm as the effectiveness of the circuit will decrease if it is loc...

Страница 4: ...N OFF ON Address 13 OFF ON ON ON OFF Address 14 OFF ON ON ON ON Address 15 ON OFF OFF OFF OFF Address 16 ON OFF OFF OFF ON Address 17 ON OFF OFF ON OFF Address 18 ON OFF OFF ON ON Address 19 ON OFF ON...

Страница 5: ...port 1 LED Input Status IN1 2 LED Input Status IN2 3 LED Input Status IN3 4 LED Input Status IN4 5 LED Input Status IN5 6 LED Input Status IN6 7 LED Input Status IN7 8 LED Input Status IN8 TMP Cabinet...

Страница 6: ...ge passed through 125mA maximum each reader Reader LED output TTL compatible high 3V low 0 5V 5mA source sink maximum Reader buzzer output Open collector 5Vdc open circuit maximum 10mA sink maximum Re...

Страница 7: ...other warranties or implied warranties and expressly excludes and disclaims all implied warranties of merchantability or fitness for a particular purpose Returned units are repaired or replaced from a...

Отзывы: