background image

 

Mercury Security © 2015 

EP1502 

DOC  10107-0031    

REV 1.06 

 Page   1 

www.mercury-security.com 

2355 MIRA MAR AVE. LONG BEACH, CA 90815-1755, (562)986-9105 FAX (562) 986-9205 

EP1502 Intelligent Controller 

with Two Reader Interface 

Installation and Specifications: 

1.  General: 

The EP1502 intelligent controller provides decision making, event reporting, and database storage for the 
Mercury hardware platform.  Two reader interfaces provide control for two physical barriers. 

The EP1502 communicates with the host via on-board 10-BaseT/100Base-TX Ethernet port.  Alternatively, 
port 1 (RS-232) can be used for host communication. 

Each  reader  port  can  accommodate  a  reader  that  utilizes  TTL  (D1/D0,  Clock/Data),  F/2F,  or  2-wire  
RS-485 device signaling, and also provides tri-state LED control, and buzzer control (one wire LED mode 
only).  Four Form-C relay outputs may be used for strike control or alarm signaling.  The relay contacts are 
rated at 5 A @ 30 Vdc, dry contact configuration.  Eight inputs are provided that may be used for monitoring 
the door contacts, exit push buttons and alarm contacts.  Input circuits may be configured as unsupervised 
or supervised.  The EP1502 requires 12 to 24 Vdc for power.   

2.  EP1502 Hardware: 

 

 

J4

J3

1

2

3

TMP

FLT

R1

R2

+

1

3

2

4

J8

R

ESE

T

S2

BT1

3V    BR/CR2330

J1

5V

3.3V

2

3

4

1

S1

VBAT

IN1

K

1
K

2
K

3
K

4

K2

K1

K3

K4

IN2

IN3

IN4

IN5

IN6

IN7

IN8

8V

J6

J2

J5

J7

PASS

12V

GND

DAT

D0

TB8

R

EA

D

ER

 1

BZR

VO

GND

FLT

GND

TMP

GND

VIN

TB1

LED

D1

CLK

R

EA

D

ER

 2

D1

LED

VO

BZR

GND

CLK

D0

DAT

TB9

NO

OUT 1 C

NC

NO

OUT 2 C

NC

NC

OUT 4 C

NC

NO

NO

OUT 3 C

TB

10

TB

11

RXD

CTS

GND

RTS

TXD

TB2

TB

3

TR+

GND

TR-

IN1

IN2

IN3

IN4

IN5

IN6

IN7

IN8

TB4

TB5
TB6

TB7

.25 [6.35]

5.50 [139.70]

.25 [6.35]

6.00 [152.40]

.50 [12.70]

2.00 [50.80]

3.00 [76.20]

2.00 [50.80]

.50 [12.70]

8.00 [203.20]

Ø.156 [3.96]
8 PLACES

RESET SWITCH

BATTERY: BR/CR2330

REPLACE ANNUALLY

-

STATUS LED's

DIP SWITCHES

RELAY

STATUS

LED's

INPUT

STATUS

LED's

CHASSIS
GROUND

This device complies with part 15 of the FCC Rules.  Operation 
is subject to the following two conditions: (1) This device may 
not  cause  harmful  interference,  and  (2)  this  device  must 
accept any interference received, including interference that 
may cause undesired operation. 

Содержание EP1502

Страница 1: ...d that may be used for monitoring the door contacts exit push buttons and alarm contacts Input circuits may be configured as unsupervised or supervised The EP1502 requires 12 to 24 Vdc for power 2 EP1...

Страница 2: ...lly Open Contact TB5 2 IN4 TB11 2 C Common TB5 3 Input 3 IN3 TB11 3 NC Normally Closed Contact TB5 4 IN3 TB11 4 Out 4 NO Normally Open Contact TB6 1 Input 6 IN6 TB11 5 C Common TB6 2 IN6 TB11 6 NC Nor...

Страница 3: ...wing purposes Erase all configuration and cardholder database sanitize board Update OEM default parameters after OEM code has been changed Recover from database corruption causing EP1502 board to cont...

Страница 4: ...ort supports a reader with TTL D1 D0 Clock Data F 2F or 2 wire RS 485 signaling Power to the readers is selectable 12 Vdc VIN must be greater than 20 Vdc or power is passed through PASS from the input...

Страница 5: ...e standard supervised circuit requires 1k ohm 1 resistors and should be located as close to the sensor as possible Custom end of line EOL resistances may be configured via the host software Grounded a...

Страница 6: ...tallation the user accounts to the web configuration page should be created with secure passwords and that all DIP switches are in the off position for the normal operating mode The EP1502 is shipped...

Страница 7: ...le See Note 1 IN3 Input IN3 Status OFF Inactive ON Active Flash Trouble See Note 1 IN4 Input IN4 Status OFF Inactive ON Active Flash Trouble See Note 1 IN5 Input IN5 Status OFF Inactive ON Active Flas...

Страница 8: ...ee from defects in material and workmanship under normal use and service with proper maintenance for one year from the date of factory shipment Mercury Security assumes no responsibility for products...

Отзывы: