Section 5 - Maintenance
Page 120
90-864839070 AUGUST 2007
17. Disconnect the quick‑connect fitting and water hose from the flush socket on the engine
by pressing the release button on the flush socket.
b
a
18488
a -
Quick‑connect fitting (water hose
end)
b -
Flush socket release button
18. Remove the quick‑connect fitting from the water hose.
18487
a
b
a -
Quick‑connect fitting (water hose
end)
b -
Water hose
19. Retain the quick‑connect fitting with the water hose end for repeated use by storing it
separately in a storage compartment on the boat for easy access.
IMPORTANT: Do not store the quick‑connect fitting in the flush socket on the engine. Doing
so would allow the seawater pump to suck air during engine operation causing an
overheating problem. Damages due to engine overheating are not covered by Mercury
MerCruiser Warranty.
25900
a
Quick‑connect fitting stored in the boat
a -
Quick‑connect fitting (water hose end)
Содержание 8.1 MAG
Страница 46: ...Section 2 Getting to Know Your Power Package Notes Page 38 90 864839070 AUGUST 2007 ...
Страница 62: ...Section 3 On The Water Notes Page 54 90 864839070 AUGUST 2007 ...
Страница 68: ...Section 4 Specifications Notes Page 60 90 864839070 AUGUST 2007 ...
Страница 70: ...Section 5 Maintenance Page 62 90 864839070 AUGUST 2007 Models Using The Sterndrive Water Pickup 117 ...
Страница 130: ...Section 5 Maintenance Notes Page 122 90 864839070 AUGUST 2007 ...
Страница 148: ...Section 7 Troubleshooting Notes Page 140 90 864839070 AUGUST 2007 ...