TRANSPORT AND STORAGE

  ______________________________________ 

 

mcr  Omega  control  unit  with  the  differential  pressure  transmitter  (mcr  ICS  or  Beck  485M)  is 

packed individually in a carton box and secured against mechanical damage. The carton box for large 
units  is  fixed  to  the  wooden  pallet.  The  unit  can  be  transported  by  any  means  provided  that  it  is 
protected against weather conditions. During transport, the unit is placed on the base plate (do not lean 
on  optical  indicators  or control fittings).  Check the  device  for  damage  during transport.  Store  indoors 
protected against weather conditions. Insulate the device when possible. 

The air supply units with auxiliary components (duct smoke detectors, shut-off dampers) for mcr 

EXi-F system (for transport and storage) are delivered on pallets.  

 

Do not throw or tilt the packaging during transport and handling. The fans can be transported by any 
means provided that they are protected against weather conditions. Protect the fans against shifting in 
transport. Check the fan for damage during transport. 
Store indoors: 

  no dust, corrosive vapours and gases or other aggressive chemical fumes which may damage 

the insulation or structural components of the motor or fan; 

 

 

  maximum relative humidity up to 80% at + 20ºC; 

  ambient temperature –20ºC to +40ºC; 

  no vibrations. 

7.

 

MAINTENANCE AND SERVICING

 ___________________________________ 

 

 

„MERCOR”  S.A.  products  require  periodical  inspections  and  maintenance  at  least  every  12 

months  throughout  its  operating  period,  i.e.  warranty  and  post-warranty  period.   Inspections  and 
maintenance  must  be  carried  out  by  the  device  manufacturer  or  a  service  centre  authorized  by 
„MERCOR” S.A. 
The service inspections of fire protection devices are required by the § 3 sec. 3 of the Regulation of the 
Minister of Interior and Administration of 7 June 2010 on fire protection of buildings, other construction 
facilities and sites (Journal of Laws Dz. U. 2010 no. 109, item 719). 
The following are recommended between inspections: 

  Check electrical connections for mechanical damage. 

  Check if the supply voltage for the devices is within the following tolerances: 

  24 V±10% for electric actuators 

  24 V±2% for electromagnetic releases 

  230 V ±10% for electrical actuators 

  24 V±2% for electromagnetic releases 

  Check device bodies for mechanical damage. 

  Check for obstacles which may affect correct operation of the devices. 

To  enable  inspections,  servicing  and  warranty  related  operations,  including checks  and  repairs, User 
must provide access to the device by removing thermal insulation, suspended ceilings and any other 
systems preventing access to the device etc. 
Install cleanout, e.g. mcr KRW for all duct-mounted devices. 
Provide access to the roof (ladder or lift) for all roof-mounted devices. 
 
For  any  issues  regarding  inspections,  maintenance  and  servicing  please  contact  „MERCOR”  S.A. 
Service Department at 

[email protected]

,  

phone 058/ 341 42 45 ext. 170 or fax 058/ 341 39 85 office hours 8 – 16 (Mon-Fri). 

 

8.

 

WARRANTY TERMS AND CONDITIONS

 ______________________________ 

 

1.  „MERCOR”  S.A.  provides  a  12-month  quality  guarantee  for  all  its  products  from  the  date  of 

purchase, unless otherwise stated in the purchase contract. 

2.  „MERCOR”  S.A.  shall  repair  any  product  defects  identified  within  the  warranty  period  within  21 

days  from  a  written  notification  and  after  providing  a  proof  of  purchase  or  purchase  contract, 
subject to par. 6. 

Содержание EXi-F

Страница 1: ...2 80 408 Gdańsk phone 0 58 341 42 45 tel fax 0 58 341 39 85 OPERATION AND MAINTENANCE MANUAL mcr EXi F pressure differential system kit for smoke and heat control systems No EXi F 005 2022 FIRE VENTILATION SYSTEM DEPARTMENT ...

Страница 2: ...DIFFERENTIAL PRESSURE TRANSMITTER 17 4 2 1 MCR ICS DIGITAL DIFFERENTIAL PRESSURE TRANSMITTER 17 4 3 AUXILIARY COMPONENTS OF MCR EXI F SYSTEM 19 4 3 1 INTAKE VENT SWITCHING SYSTEM 19 4 3 2 DUCT SMOKE DETECTOR UG 3 A4 20 4 3 3 MANUAL CONTROL PANEL MCP 21 5 WIRING SYSTEM 22 5 1 MCR OMEGA CONTROL SUPPLY UNIT 22 5 2 MCR EXI F AIR SUPPLY UNITS 23 5 3 MCR ICS PRESSURE TRANSMITTERS 24 5 3 1 MCR ICS DIGITA...

Страница 3: ...anual applies to mcr EXi F positive pressure smoke control system for escape routes The system includes a group of products selected and configured to establish a protected area with a specific positive pressure in accordance with the design requirements The system is manufactured by MERCOR SA ul Grzegorza z Sanoka 2 80 408 Gdańsk mcr EXi F system components 1 mcr Omega control unit CU Omega 2 mcr...

Страница 4: ...ss mcr EXi F system can be used in staircases with protected lobbies and is compatible with systems including at least one pressure transmitter per protected area mcr EXi F system consists of a configured set of devices preventing smoke ingress to the protected area by increasing pressure Fig 1 Example mcr EXi F system diagram Depending on the demand air can be supplied to the protected area using...

Страница 5: ...d by a variable air volume supplied to the protected area by the air supply unit s Provided that the door to the protected area are closed the main fan of the air supply unit maintains a stable positive pressure The actual pressure in the protected area is measured and controlled by mcr ICS The positive pressure in the staircase 20 80 Pa guarantees that the force required to open the exit door doe...

Страница 6: ...EXi F positive pressure smoke control system MERCOR S A Specifications are subject to change without notice Version DTR_EXIF_EN_20220516 Page 6 28 Fig 2 Example positive pressure mcr EXi F system ...

Страница 7: ...ply fan with damper and smoke detector air supply fan with damper and smoke detector air supply fan with damper and smoke detector mcr Omega control unit mcr Omega control unit mcr Omega control unit air supply fan with damper and smoke detector CORRIDOR STAIRCASE STAIRCASE CORRIDOR CORRIDOR STAIRCASE a single point air supply b two point air supply c multi point air supply air supply fan with dam...

Страница 8: ...hnical conditions for buildings and their location Dz U No 75 of 2002 item 690 as amended Technical Approval ITB KOT 2021 1788 4 SYSTEM COMPONENTS __________________________________________ 4 1 mcr Omega control unit ___________________________________________________ Applications _______________________________________________________ mcr EXi F pressure differential system kit uses mcr Omega cont...

Страница 9: ... system MERCOR S A Specifications are subject to change without notice Version DTR_EXIF_EN_20220516 Page 9 28 Fig 5 Example mcr EXi F system control configuration diagram Operation__________________________________________________________ ...

Страница 10: ...red by an incoming panel for fire protection equipment which is not being disconnected with a fire switch or is equipped with an automatic reserve power switch ARPS in buildings where no incoming panel for fire protection equipment is available in the main switchboard mcr Omega control unit is delivered in powder coated on stainless steel enclosure with front door and IP55 protection rating extern...

Страница 11: ...t precipitation and solar radiation is required in external use power supply and control of smoke control devices and fire divisions which require auxiliary power supply as per relevant regulations Control unit components depending on the system size automatics and control block with advanced microprocessor monitoring and control modules mcr MMS and intelligent mcr ICR positive pressure regulator ...

Страница 12: ...no alarm If the contact is opened the controller reads the resistor resistance and executes a program stored in its memory If the resistance at the controller input increases to infinity the unit treats it as a failure indicates the status with controller lights and transmits a signal After installing and checking the correct operation of all system components the system starts the adaptation proc...

Страница 13: ...ith optional accessories mcr EXI F air supply unit a multi blade damper with BLF BF BFL BFN BLE BE NMQ LMQ SMQ NF SF or MF MLF series actuator b duct smoke detector optional c mcr LAM exhaust vent vertical installation of fans in box housing converging pipe with flange beveled duct with grille mcr EXi F air supply units include mcr Monsun E1 series axial fans in a box type housing Air supply fans ...

Страница 14: ...nditions with mcr LAM louver vents Fig 13 The declared properties and features of LAM vent e g snow load SL 1300 wind load WL 1500 guarantee operation in extreme weather conditions For vertical installation indoors the unit is mounted on the supporting structure and connected to the air supply system in accordance with the design requirements mcr EXI F air supply units include multi blade dampers ...

Страница 15: ...0 238 5 mcr EXi F 80 1S 1000 1000 900 900 810 130 200 115 640 60 156 6 mcr EXi F 71 1S 1000 1000 900 900 810 130 200 115 640 60 156 7 mcr EXi F 71 2S 1000 1000 900 900 810 130 200 115 640 60 156 8 mcr EXi F 63 1S 825 825 700 700 710 130 200 115 525 60 101 Item System type A mm B mm C mm D mm d mm 1 mcr EXi F 100 1S 1200 1150 860 884 13 2 mcr EXi F 100 2S 1200 1150 860 884 13 3 mcr EXi F 90 1S 1200...

Страница 16: ...200 1200 1300 1300 300 750 320 326 5 mcr EXi F 80 1S H 1000 1000 1100 1100 300 650 320 228 6 mcr EXi F 71 1S H 1000 1000 1100 1100 300 650 320 228 7 mcr EXi F 71 2S H 1000 1000 1100 1100 300 650 320 228 8 mcr EXi F 63 1S H 825 825 945 945 300 550 320 157 Fig 10 Dimensions and weights of mcr EXi F air supply kit with fan in box housing Fig 11 Example mcr EXi F air supply unit in wall mounted versio...

Страница 17: ... air supply unit 1 fan in box housing 2 ventilation duct 3 damper 4 duct smoke detector 5 flexible connector 6 fan inlet protection 7 junction box 9 noise suppresor 4 2 Differential pressure transmitter ____________________________________________ 4 2 1 mcr ICS digital differential pressure transmitter ______________________________ The device measures differential pressure in a protected area at ...

Страница 18: ...end periodical status information to the regulator to ensure continuous monitoring of the system status and detection of the following failures line discontinuity mcr ICS digital pressure transmitter removed or faulty alarm input discontinuity for mcr ICS digital pressure transmitter failure for mcr ICS The pressure source is connected via a flexible 8 mm dia pressure line 5 m pressure line includ...

Страница 19: ..._________________ If the air inlets are at the roof level two air inlets are required distant from each other and facing different direction to avoid leeward position in relation to the smoke source Each inlet should provide full air supply required by the system All inlets should be protected by an independent system of smoke control dampers when one damper closes due to the smoke another inlet w...

Страница 20: ...r UG 3 A4 _____________________________________________ If the air inlet is not at the roof level in the inlet duct or directly near the air supply ducts a smoke detector for automatic deactivation of the pressure differential system should be provided in case when large volumes of smoke are present in the supplied air If the air inlets are at the roof level two air inlets are required two intake ...

Страница 21: ... fire fighting operations The panel should be located near the fire exits and easily accessible to the rescuers The panel indicates unit operation status power supply green light ON indicates correct system operation failure yellow light ON indicates system failure alarm red light ON indicates alarm lock blinking yellow light indicates manual lock air inlet fan operation green light ON indicates a...

Страница 22: ...ff dampers power supply and operation of the duct smoke detector power supply control and monitoring of dampers used in differential pressure system The control unit is supplied with 3 x 400 V The control supply unit is powered by an incoming panel for fire protection equipment which is not disconnected with a fire switch or is equipped with an automatic reserve power switch ARPS in buildings wher...

Страница 23: ...d Omega unit up to 50 m Table 5 List of recommended power cable types for mcr EXi F auxiliary devices recommended cross sections calculated for the distance between the control devices and Omega unit up to 50 m 5 2 mcr EXI F air supply units mcr EXI F air supply units can be fitted with service switches for cutting off fan power supply before inspection or maintenance Fig 20 Wiring diagram for the...

Страница 24: ...itters connected to mcr Omega control supply unit are installed in the protected lobbies A fire signal for a specific floor is provided for each controller In case of a fire mcr ICS assigned to a specific floor is activated The pressure is adjusted based on the read outs from the activated mcr ICS pressure transmitter Note Pressure line connection polarity does not affect measurement accuracy sinc...

Страница 25: ...sure line length should not exceed 12 m Additional set of pressure lines include 4 fittings 2 elbows and 2 straight connectors Fig 23 Additional pressure line set with accessories Pressure system outside the building should be made with silicone pressure lines resistant to low temperature Protect the ends of the hydraulic lines against accidental blocking Use back boxes with pre drilled holes in t...

Страница 26: ... mcr EXI F air supply units Belimo BE actuators no spring return are used in dampers in the intake vent switching system Fig 25 Wiring diagram for Belimo BE BLE actuator in two intake vent switching system 5 5 Duct smoke detector The duct smoke detector features relay outputs indicating alarm smoke detecting and technical alarm service Fig 26 Duct smoke detector wiring diagram Power supply Alarm o...

Страница 27: ... and post warranty period Inspections and maintenance must be carried out by the device manufacturer or a service centre authorized by MERCOR S A The service inspections of fire protection devices are required by the 3 sec 3 of the Regulation of the Minister of Interior and Administration of 7 June 2010 on fire protection of buildings other construction facilities and sites Journal of Laws Dz U 20...

Страница 28: ...ssive external factors in particular chemical and biological factors arising from the production processes and activities on site or in the vicinity of the device natural wear and tear e g gaskets unless an inherent defect was identified damage due to the incorrect transport unloading and storage damage due to the failure to follow the installation instruction in the Operation and Maintenance Manu...

Отзывы: