background image

 

 

 2 of 7 

Document Number: MER_IS_0009    8197479  06/2018 

Subject:

 MHC Installation Instructions 

       

 

 

5.

 

Remove old cabinets and clean counters / floors as needed. Each store may have Duke 
cabinets that are new enough to save and use in other locations.  You may be asked to 
remove, clean, and shipped to another location as an addition to the installation 
pricing.  

    

 

 

6.

 

Plug in new Merco Cabinets and pre-heat. (approx. 15 minutes) The screen will 
display a brown segment slowly covering the yellow as it gets close to set point. 

                                                                        

                                         

7.

 

Verify connectivity between all cabinets by looking at the 
icon on the touchscreen U.I. (See photo above). 

8.

 

Verify correct menu for the cabinet has been selected.   

 

 

Pre-Heating 
Screen 

“Connectivity Icon” 
Number should equal 
the number of cabinets 
in the store. 

Содержание MHC22SNT1T

Страница 1: ...cles will be s 5 15R 5 20R L5 30R to match the plugs listed below This may have to be done with a site visit Domestic Model Voltage Cycle Phase Watts Amps Plug MHC22SNT1T 120V 60H 1Ph 660 5 5 5 15P MH...

Страница 2: ...ped to another location as an addition to the installation pricing 6 Plug in new Merco Cabinets and pre heat approx 15 minutes The screen will display a brown segment slowly covering the yellow as it...

Страница 3: ...Instructions 9 Press the USB Icon from the home screen 10 Press the lock icon 11 Enter code 159357 and press the GREEN check button 12 Press and hold the refresh button for 3 seconds 13 The menus are...

Страница 4: ...e home screen see Figure 10 18 On the next screen press the row of dots at the bottom of the screen see Figure 11 19 The tools options menu is displayed Press the System Information button see Figure...

Страница 5: ...for edit have a shaded box see Figure 17 24 Press the shaded box and use the pop up keyboard to enter the data see Figure 18 25 Repeat for each field of data 26 When finished entering the data press t...

Страница 6: ...the others in gray There is no change is countdown or timer behavior When the first item is canceled or reset the next one in order will turn green Use Highlighted Tray First Lid Requirements No line...

Страница 7: ...mitter Router The RFID identifier is built into the RFID collars above The collars are placed on a holding tray and initialize the unique holding time and temperature for that product in the first hol...

Отзывы: